English
Language : 

CPF5US03 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC PCB Mount
AC-DC PCB Mount
5-10 Watts
CPF Series
THE XPERTS IN POWER
•
PCB Mounting
•
Low Cost
•
Universal Input
•
Small Footprint
•
Rugged Design
•
Surface Mount Technology
•
Accessory Mounting Boards
Specification
Input
General
Input Voltage
• 85-264 VAC (110-370 VDC)
Efficiency
• See Table
Input Frequency
Input Current
Inrush Current
Earth Leakage
Current
• 47-440 Hz
• 0.3 A max (110 VAC Io = 100%)
• 15 A typical (110 VAC Io = 100%),
30 A typical (230 VAC = Io 100%)
at cold start
• 0.5 mA max at 230 VAC 60 Hz
Isolation
•
Switching Frequency •
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
100 kHz typical
Environmental
Operating
•
Temperature
-10 °C to +55 °C (derate linearly above
+55 °C to 25% at +70 °C)
Output
Output Voltage
• See Table
Minimum Load
• No minimum load required
Start-Up Delay
• 700 ms max at rated input & load
Hold-Up Time
• 10 ms min
Initial Set Accuracy • -3%, +6% max
Storage
Temperature
Humidity
Shock
Vibration
• -20 °C to +75 °C
• 20-95% RH non-condensing
• 20 G 11 ms once each X, Y & Z axis
• 2 G 10-55 Hz 3 min period for 60 mins
along X, Y & Z axis
Drift
• 0.6% max
EMC & Safety
Line Regulation
• See Table
Emissions
• EN55022 Level B conducted
Load Regulation
• See Table
EN55022 Level B radiated
Ripple & Noise
Overvoltage
Protection
Overcurrent
Protection
• 260 mV pk-pk max, 20 MHz bandwidth ESD Susceptibility
• Operates >115% Vnom, clamps by
zener diode
• Operates >125% of rating,
auto recovery
Radiated
Susceptibility
EFT/Burst
• EN61000-4-2 Level 3 Air,
Level 2 Contact
• EN61000-4-3 Level 3
• EN61000-4-4 Level 3
Temperature
Coefficient
• 0.04%/°C
Surge
• EN61000-4-5 Level 3 line to line,
Level 4 line to ground
Safety Approvals
• UL1950, C-UL, EN60950, VDE 0160
•
www.xpplc.com
•