CPF5US03 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC PCB Mount | |||
|
AC-DC PCB Mount
5-10 Watts
CPF Series
THE XPERTS IN POWER
â¢
PCB Mounting
â¢
Low Cost
â¢
Universal Input
â¢
Small Footprint
â¢
Rugged Design
â¢
Surface Mount Technology
â¢
Accessory Mounting Boards
Specification
Input
General
Input Voltage
⢠85-264 VAC (110-370 VDC)
Efficiency
⢠See Table
Input Frequency
Input Current
Inrush Current
Earth Leakage
Current
⢠47-440 Hz
⢠0.3 A max (110 VAC Io = 100%)
⢠15 A typical (110 VAC Io = 100%),
30 A typical (230 VAC = Io 100%)
at cold start
⢠0.5 mA max at 230 VAC 60 Hz
Isolation
â¢
Switching Frequency â¢
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
100 kHz typical
Environmental
Operating
â¢
Temperature
-10 °C to +55 °C (derate linearly above
+55 °C to 25% at +70 °C)
Output
Output Voltage
⢠See Table
Minimum Load
⢠No minimum load required
Start-Up Delay
⢠700 ms max at rated input & load
Hold-Up Time
⢠10 ms min
Initial Set Accuracy ⢠-3%, +6% max
Storage
Temperature
Humidity
Shock
Vibration
⢠-20 °C to +75 °C
⢠20-95% RH non-condensing
⢠20 G 11 ms once each X, Y & Z axis
⢠2 G 10-55 Hz 3 min period for 60 mins
along X, Y & Z axis
Drift
⢠0.6% max
EMC & Safety
Line Regulation
⢠See Table
Emissions
⢠EN55022 Level B conducted
Load Regulation
⢠See Table
EN55022 Level B radiated
Ripple & Noise
Overvoltage
Protection
Overcurrent
Protection
⢠260 mV pk-pk max, 20 MHz bandwidth ESD Susceptibility
⢠Operates >115% Vnom, clamps by
zener diode
⢠Operates >125% of rating,
auto recovery
Radiated
Susceptibility
EFT/Burst
⢠EN61000-4-2 Level 3 Air,
Level 2 Contact
⢠EN61000-4-3 Level 3
⢠EN61000-4-4 Level 3
Temperature
Coefficient
⢠0.04%/°C
Surge
⢠EN61000-4-5 Level 3 line to line,
Level 4 line to ground
Safety Approvals
⢠UL1950, C-UL, EN60950, VDE 0160
â¢
www.xpplc.com
â¢
sales@xpplc.com
|
▷ |