CPC15UT1 Datasheet, PDF (1/4 Pages) XP Power Limited – Triple Output Switchers | |||
|
Triple Output Switchers
15-60 Watts
CPC Series
THE XPERTS IN POWER
â¢
Low Profile
â¢
Small, Compact PCB Format
â¢
Isolated Auxiliary Outputs
â¢
Low Noise
â¢
85-264 VAC Universal Input
â¢
Optional Covers & Looms
â¢
International Safety Approvals
Specification
Input
Input Voltage
Input Frequency
Inrush Current
⢠85-264 VAC (110-370 VDC)
⢠47-440 Hz
⢠60 A max at 200 V input & full load
(cold start)
Output
Hold-Up Time
â¢
Output Voltage
â¢
Output Voltage
â¢
Adjustment
Output Voltage
â¢
Set Point
Line Regulation
â¢
Load Regulation
â¢
Ripple & Noise
â¢
Minimum Load
â¢
Short Circuit &
â¢
Overload Protection
Overvoltage
â¢
Protection
10 ms min at 85 V input & full load
(100 ms typical at 200 V input)
See Table, 5 V adjustable,
V1 is isolated from V2 & V3
5 V ±5%
±6% max
0.4% max over specified input range
2% 5 V output,
1% auxiliary outputs
40 mV pk-pk typical
(180 mV pk-pk max)
No minimum load - See Note 3
Operates >105% of rating
auto recovery
Operates >115% of rating +5 V output
General
Switching Frequency â¢
Efficiency
â¢
Variable frequency 40-400 kHz
dependant on line & load
70-72% typical
Isolation
⢠Input to output 3000 VAC for 1 min,
500 VDC, 50 Mohm
Input to earth 2000 VAC for 1 min,
500 VDC, 50 Mohm
Output to earth 500 VAC for 1 min,
500 VDC, 50 Mohm
Leakage Current
⢠0.75 mA max.
Mating Connectors ⢠Available as an option
Cable Looms
⢠Available as an option
Covers
⢠Available as an option
Environmental
Operating
â¢
Temperature
Storage
â¢
Temperature
Relative Humidity â¢
Vibration
â¢
Shock
â¢
-10°C to +70°C, derate above +50 °C
Consult Sales Office
-20 °C to +75 °C
20-90% non-condensing
10-55 Hz at 2 G, 3 mins period for
60 mins along X, Y & Z axis
20 G for 11 ms, once on X, Y & Z axis
EMC & Safety
EMC
â¢
Safety Approvals
â¢
FCC curve B, EN55022B
Approved to UL1950, IEC950,
CSA22.2 No.234, EN60950
â¢
www.xpplc.com