English
Language : 

CPB600PS3V3 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Chassis Mount
AC-DC Chassis Mount
400-650 Watts
CPB600 Series
THE XPERTS IN POWER
•
Universal PFC Input
•
Low Profile (61mm)
•
Wide Output Voltage Adjustment
•
Remote ON/OFF
•
Power Good Signal
•
Remote Sense
•
Peak Current Available
Specification
Input
Input Voltage
•
Input Frequency
•
Input Current
•
Inrush Current
•
Power Factor
•
Earth Leakage
•
Current
Output
Output Voltage
•
Output Voltage
•
Adjustment
Minimum Load
•
Start-Up Time
•
Hold-up Time
•
Drift
•
Line Regulation
•
Load Regulation
•
Ripple & Noise
•
Overvoltage
•
Protection
Overload Protection •
Temperature
•
Coefficient
Overtemperature
•
Protection
Remote Sense
•
95-264 VAC (120-370 VDC)
47-63 Hz
8.2 A max at 115 VAC
40 A max at 230 VAC
0.98/0.95 at 115/230 VAC
0.75 mA max at 230 VAC 60 Hz
See Table
See Table
No minimum load required
400 ms typical at 230 VAC, 100% load
20 ms typical at 100% load
±0.4% max
±0.5% max
±1.0% max 0-100% load
± 1% max pk-pk 20 MHz bandwidth
110-130% of Vnom
Recycle input to reset
Operates at 105% of rated current
(101% of pk rating), <5 s auto recovery
>5 s recycle input to reset
±1.25% max -20 °C to +50 °C
Operates in the event of fan failure
or if the operating temperature/
derating criteria is exceeded
Compensates for 0.3 V drop max
If not required sense terminals
must be connected locally
ie: +S to +M and -S to -M on CN1
Remote ON/OFF
• 12 V 3 mA applied between RCG &
RC2 will inhibit the output of the unit
& the fan
General
Efficiency
•
Isolation
•
Switching Frequency •
See Table
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
130kHz PFC, 330 kHz PWM
Environmental
Operating
•
Temperature
Storage
•
Temperature
Relative Humidity •
Shock
•
Vibration
•
-20 °C to +70 °C, derate linearly above
+50 °C to 50% at +70°C
-20 °C to +75 °C
20-90% non condensing
20 G 11 ms, once each x, y and z axis
2 G 10-55Hz for 3 min periods for
60 min along each x, y and z axis
EMC & Safety
Emissions
•
ESD
•
Susceptibility
Radiated
•
Susceptibility
EFT/Burst
•
Surge
•
Safety Approvals
•
EN55022 Level B conducted
EN55022 Level A radiated
EN61000-4-2 Level 2 contact,
Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA 60950) EN60950
•
•
www.xpplc.com