CLC125 Datasheet, PDF (1/2 Pages) XP Power Limited – 125 Watts CLC Series
125 Watts
CLC Series
xppower.com
• 125 W Forced cooled Rating
• Low Profile 1.25”
• Industry Standard 2” x 4” & 3” x 5” Package Sizes
• 12 V Fan Supply
• Optional ORing Diode
• <0.5 W No Load Input Power
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Earth Leakage Current
Input Protection
• 85-264 VAC (120-370 VDC),
Derate output power linearly to 90% from
90 VAC to 85 VAC
• 47-63 Hz
• 2.3 A typical at 115 VAC, full load
1.1 A typical at 230 VAC, full load
• 40 A max at 230 VAC, cold start 25 °C
• EN61000-3-2, class A
• <0.5 W
• 80/160 µA typical 115/230 VAC 50 Hz
300 µA at 264 VAC/60 Hz max.
• Internal T5 A/250 V fuse in line
Output
Output Voltage
• 12-48 VDC (see tables)
Output Voltage Trim • ±10%
Initial Set Accuracy • ±1%
Minimum Load
• No minimum load required
Start Up Delay
• 1 s typical
Start Up Rise Time
• 50 ms
Hold Up Time
• 16 ms min at 230 VAC
Drift
• ±0.2% after 20 min warm up
Line Regulation
• ±0.5% max
Load Regulation
• ±1%
Over/Undershoot
• 5% typical
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
• 1% pk-pk V1, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection • 110-150%
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Temperature
Coefficient
• 0.05%/˚C
General
Efficiency
Isolation
Switching Frequency
MTBF
• 88% typical
• 3000 VAC Input to Output, 1500 VAC
Input to Ground, 500 VDC Output to
Ground
• 65 KHz typical
• 1,245 KHrs to Telecordia SR-332
at 25 °C, GB
Environmental
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C
at 2.5%/˚C to 50% load at +70 ˚C.
Cooling
• Forced cooled, 10 CFM
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 kHz, 3 axes
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level as below
Emissions
• EN55022 level B conducted
EN55022 level A radiated
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV EN60950-1
Equipment Protection • Class I
Class