CLC125 Datasheet, PDF (1/2 Pages) XP Power Limited – 125 Watts CLC Series | |||
|
125 Watts
CLC Series
xppower.com
⢠125 W Forced cooled Rating
⢠Low Profile 1.25â
⢠Industry Standard 2â x 4â & 3â x 5â Package Sizes
⢠12 V Fan Supply
⢠Optional ORing Diode
⢠<0.5 W No Load Input Power
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Earth Leakage Current
Input Protection
⢠85-264 VAC (120-370 VDC),
Derate output power linearly to 90% from
90 VAC to 85 VAC
⢠47-63 Hz
⢠2.3 A typical at 115 VAC, full load
1.1 A typical at 230 VAC, full load
⢠40 A max at 230 VAC, cold start 25 °C
⢠EN61000-3-2, class A
⢠<0.5 W
⢠80/160 µA typical 115/230 VAC 50 Hz
300 µA at 264 VAC/60 Hz max.
⢠Internal T5 A/250 V fuse in line
Output
Output Voltage
⢠12-48 VDC (see tables)
Output Voltage Trim ⢠±10%
Initial Set Accuracy ⢠±1%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠1 s typical
Start Up Rise Time
⢠50 ms
Hold Up Time
⢠16 ms min at 230 VAC
Drift
⢠±0.2% after 20 min warm up
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1%
Over/Undershoot
⢠5% typical
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
⢠1% pk-pk V1, 20 MHz bandwidth
Overvoltage Protection ⢠115-140% Vnom, recycle input to reset
Overload Protection ⢠110-150%
Short Circuit Protection ⢠Continuous trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.05%/ËC
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠88% typical
⢠3000 VAC Input to Output, 1500 VAC
Input to Ground, 500 VDC Output to
Ground
⢠65 KHz typical
⢠1,245 KHrs to Telecordia SR-332
at 25 °C, GB
Environmental
Operating Temperature ⢠0 ËC to +70 ËC derate linearly from +50 ËC
at 2.5%/ËC to 50% load at +70 ËC.
Cooling
⢠Forced cooled, 10 CFM
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 ËC to +85 ËC
Operating Altitude
⢠3000 m
Shock
⢠30 g pk, half sine, 6 axes
Vibration
⢠2 g rms, 5 Hz to 500 kHz, 3 axes
EMC & Safety
Low Voltage PSU EMC ⢠EN61204-3, high severity level as below
Emissions
⢠EN55022 level B conducted
EN55022 level A radiated
Harmonic Currents
⢠EN61000-3-2, class A
Voltage Flicker
⢠EN61000-3-3
Radiated Immunity
⢠EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
⢠EN61000-4-4, level 3 Perf Criteria A
Surge
⢠EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity ⢠EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
⢠IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV EN60950-1
Equipment Protection ⢠Class I
Class
|
▷ |