CCH400-600-SERIES Datasheet, PDF (1/2 Pages) XP Power Limited – 400/600 Watts | |||
|
400/600 Watts
CCH400 600 Series
xppower.com
⢠Baseplate Cooled
⢠High Efficiency up to 90%
⢠40 °C to +70 °C Operation
⢠Industrial & MIL STD461E EMC Compliance
⢠Power Fail, Inhibit, Overtemp & Current Share
⢠5V Standby Output
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
⢠90-264 VAC
⢠47-400 Hz(1)
⢠CCH400: 4.3/2.1 A typ. at 115/230 VAC,
CCH600: 6.3/3.1 A typ. at 115/230 VAC,
full load
⢠60 A max at 230 VAC, 25 °C cold start
⢠>0.9
⢠0.7/1.1 mA at 115/230 VAC at 60/50 Hz
⢠Internal F10 A/250 V fuse
Output
Output Voltage
⢠12-48 VDC
Output Voltage Trim ⢠±10%
Initial Set Accuracy ⢠±1% V1, ±3% V2
Minimum Load
⢠No minimum load required
Start Up Delay
⢠Typically 1 s
Start Up Rise Time
⢠50 ms typical
Hold Up Time
⢠20 ms min
Drift
⢠±0.2% after 20 min warm up
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1% V1, ±5% V2 max
Over/Undershoot
⢠1% typical
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
⢠Typically 1% pk-pk V1, V2 2%,
20 MHz bandwidth
Overvoltage Protection ⢠110-140% Vnom, recycle input to reset
Overload Protection ⢠105-140% V1 only
Short Circuit Protection ⢠Continuous, approximately constant
current
Temperature
Coefficient
⢠0.05%/ËC
Overtemp. Protection ⢠Fitted
Remote Sense
⢠Compensates for 0.5 V total voltage drop
Remote On/Off
⢠Uncommitted isolated optocoupler diode,
powered diode inhibits V1
Notes
1. Safety approvals cover frequency 47-63 Hz.
General
Efficiency
Isolation
Switching Frequency
Signals
MTBF
⢠89% typical
⢠3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
⢠30-333 kHz PFC, 51.1 kHz main and
138 kHz standby converter
⢠Power Fail, Inhibit, Current Share,
Overtemperature Warning and 5 V Standby
⢠300 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠-40 ËC to +70 ËC ambient. Baseplate must
be maintained â¤+85 °C, see thermal
considerations
Cooling
⢠Baseplate, conduction cooling
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 ËC to +85 ËC
Operating Altitude
⢠3000 m
Shock
⢠MIL-STD 810F Clause 516.5 proc 1
Vibration
⢠MIL-STD 810F figure 514.5C-17
EMC & Safety
Low Voltage PSU EMC ⢠EN61204-3, high severity level
Emissions
⢠EN55022 level B conducted, level A
radiated, MIL-STD 461D-F, CE102
Harmonic Currents
⢠EN61000-3-2, class A
Voltage Flicker
⢠EN61000-3-3
Radiated Immunity
⢠EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
⢠EN61000-4-4, level 3 Perf Criteria A
Surge
⢠EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity ⢠EN61000-4-6, level 3 Perf Criteria A,
MIL-STD 461 CS114
Dips & Interruptions
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
⢠IEC60950-1 CB report, UL60950-1, TUV
EN60950-1
Equipment Protection ⢠Class I
Class
|
▷ |