English
Language : 

ASB110 Datasheet, PDF (1/4 Pages) XP Power Limited – No Extra Components Required
ASB110 Series
AC-DC Power Supplies
110 Watts
• Complete AC/DC Power Supply
• No Extra Components Required
• Base Plate Cooled
• -40 to +85 °C Base Plate Temperature
• Low Profile in Full Brick Package
• High Efficiency - Up to 91%
• Universal Input
• <0.3 W No Load Input Power
• Optional Heatsink Available
• Over Current, Over Voltage and Over Temperature Protection
• 3 Year Warranty
The ASB110 series is a range of complete low profile, full brick, base-plate cooled AC-DC power
supplies which require no external components. The series includes a complete built in EMC filter
and AC Fuse as well as bulk storage capacitor providing a complete AC-DC power solution ready
for installation into end applications. The ASB110 offers high efficiency to minimise waste heat and
heat sinking requirements and operates from -40 °C to +85 °C on the module base-plate.
Dimensions:
ASB110:
4.6 x 2.4 x 0.67” (116.8 x 61 x 17 mm)
Models & Ratings
Output Power
Output Voltage
110 W
12.0 V
15.0 V
24.0 V
28.0 V
36.0 V
48.0 V
Notes
1. Typical efficiency with 230 VAC input and full load.
2. Add suffix ‘-HK- to receive with optional heat-sink fitted.
Output Current
9.17 A
7.33 A
4.58 A
3.93 A
3.06 A
2.29 A
Noise and Ripple
120 mV
150 mV
240 mV
280 mV
360 mV
480 mV
Efficiency(1)
90.0%
90.0%
91.0%
91.0%
91.0%
90.5%
Model Number(2)
ASB110PS12
ASB110PS15
ASB110PS24
ASB110PS28
ASB110PS36
ASB110PS48
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
No Load Input Power
Input Protection
Minimum
Typical
Maximum
85
264
47
63
1.1/0.6
70
>0.9
500
0.3
Internal T3.15A/250 VAC fitted in line
Units
VAC
Hz
A
A
µA
W
Notes & Conditions
Derate linearly from 100% load at 90 VAC to 90% load
at 85 VAC
115 VAC/Measured at 230 VAC
230 VAC, cold start at 25 °C
Full load
264 VAC, 60 Hz
General
Characteristic
Efficiency
Isolation: Input to Output
Input to Ground
Output to Ground
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Minimum
Typical
90
70-130 / 50-90
14.8
>300
0.51 (230)
Maximum
3000
1500
500
Units
%
VAC
VAC
VDC
kHz
W/in3
kHrs
lb (g)
Notes & Conditions
See Models and Ratings table
PFC / PWM
MIL-HDBK-217F at 25 °C GB
1