English
Language : 

AMM90PS05 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
90 Watts
AMM90 Series
xppower.com
• CEC2008 & EISA2007 Compliant ≥12V
• Worldwide Medical Approvals
• Small Size/High Power Density
• Class I and Class II Versions
• Operating Temperature up to +60 °C
• High Efficiency
• Locking Output Connector ≥15 V
Specification
Input
Input Voltage
• 90-264 VAC
Input Frequency
• 47-63 Hz
Input Current
• 1.2 A rms at 115 VAC,
0.6 A rms at 230 VAC
Inrush Current
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
• 0.98 typical
Earth Leakage Current • 90 µA max at 115 VAC/60 Hz,
(Class I Versions)
150 µA max at 230 VAC/50 Hz
Input Protection
• Internal 2.5 A fuse in live & neutral lines
Output
Output Voltage
• 5 to 48 VDC
Output Voltage Trim • Not user-adjustable
Initial Set Accuracy • ±2 %
Minimum Load
• No minimum load required
Start Up Delay
• 2 s max at 115 VAC
Start Up Rise Time
• <80 ms at 115 VAC
Hold Up Time
• 15 ms minimum at full load & 115 VAC
Line Regulation
• 0.5% maximum
Load Regulation
• See table
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 112-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, auto recovery
Overload Protection • 110-200%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 78% min for 5 V, 6 V & 9 V models
85% minimum for all others
• 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
• 50-110 kHz variable
• 3.4 W/In3
• 150 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Cooling
• Convection-cooled
Operating Humidity • 10-95% RH, non-condensing
Storage Temperature • -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55011/FCC/VCCI, Class B conducted
EN55011/FCC/VCCI, Class B radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
• EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B (Perf Criteria A, A, B
with 70% load)
• EN60601-1, UL60601-1,
CSA22.2 No. 601-1 per cUL, CE Mark