120 Watts
AML120 Series
xppower.com
⢠Energy Star Level V ⥠18 V
⢠CEC 2008 & EISA 2007 Compliant â¥15V
⢠High Power Density
⢠Single Outputs from 12 V to 48 V
⢠High Efficiency
⢠0 °C to +70 °C Operating Temperature
⢠Non-standard Connectors Available
Specification
Input
Input Voltage
⢠90-264 VAC
Input Frequency
⢠47-63 Hz
Input Current
⢠1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
Inrush Current
⢠60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
⢠0.98 typical at 115 VAC
Earth Leakage Current ⢠150 µA max at 115 VAC, 60 Hz
250 µA max at 230 VAC, 50 Hz
Input Protection
⢠Internal 3 A fuse
Standby Power
Consumption
⢠<0.75 W
Output
Output Voltage
⢠12 to 48 VDC
Output Voltage Trim ⢠Not user-adjustable
Initial Set Accuracy ⢠±2%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2 s max at 115 VAC
Start Up Rise Time
⢠<80 ms at 115 VAC
Hold Up Time
⢠15 ms minimum at full load and 115 VAC
Line Regulation
⢠±0.5% maximum
Load Regulation
⢠See table
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠2% max pk-pk (see note 1)
Overvoltage Protection ⢠110-140% Vnom, recycle input to reset
Overtemperature
Protection
⢠Unit shuts down, recycle input to reset
Overload Protection ⢠110-150%, auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠86% typical,
80% min for 12 V & 15 V models
⢠3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
⢠20-110 kHz variable
⢠4.9 W/In3
⢠>100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate from 100% power
at +50 °C to 60% power at +70 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠10-95% RH, non-condensing
Storage Temperature ⢠-20 °C to +80 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g, 10 ms on 3 axes
Vibration
⢠5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, level 3 Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, 10 V Perf Criteria A
⢠EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark
|
▷ |