xppower.com
• Energy Star Level V ≥18 V
• CEC 2008 & EISA 2007 Compliant ≥15V
• High Power Density
• Single Outputs from 15 V to 48 V
• High Efficiency
• 0 °C to +70 °C Operating Temperature
• Non standard Connectors Available
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
Standby Power
Consumption
• 90-264 VAC
• 47-63 Hz
• 1.6 A rms at 115 VAC,
0.8 A rms at 230 VAC
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
• 0.98 typical at 115 VAC
• 150 µA max at 115 VAC, 60 Hz
250 µA max at 230 VAC, 50 Hz
• Internal 3 A fuse
• <0.5 W
Output
Output Voltage
• 15 to 48 VDC
Output Voltage Trim • Not user-adjustable
Initial Set Accuracy • ±2%
Minimum Load
• No minimum load required
Start Up Delay
• 2 s max at 115 VAC
Start Up Rise Time
• <80 ms at 115 VAC
Hold Up Time
• 15 ms minimum at full load and 115 VAC
Line Regulation
• ±0.5% maximum
Load Regulation
• See table
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Overload Protection • 110-150%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 87% typical,
80% min for 15 V models
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 20-110 kHz variable
• 4.9 W/In3
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +50 °C to 60% power at +70 °C
Cooling
• Convection-cooled
Operating Humidity • 10-95% RH, non-condensing
Storage Temperature • -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
• EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark