AMD150PS12 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
150 Watts
AMD150 Series
xppower.com
⢠Energy Star Level V
⢠CEC2008 & EISA2007 Compliant
⢠Universal Input
⢠High Efficiency
⢠0 °C to +70 °C Operating Temperature
⢠Non-standard Connectors Available
⢠International Safety Approvals
Specification
Input
Input Voltage
⢠90-264 VAC
Input Frequency
⢠47-63 Hz
Input Current
⢠2.0 A rms at 115 VAC,
1.0 A rms at 230 VAC
Inrush Current
⢠60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
⢠0.95 typical
Earth Leakage Current ⢠150 µA max at 115 VAC,
250 µA max at 230 VAC
No Load Input Power ⢠<0.5 W
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠Not user-adjustable
Initial Set Accuracy ⢠±2%
Minimum Load
⢠No minimum load required
Start Up Delay
⢠5 s max at 100 VAC
Hold Up Time
⢠3 ms minimum at 100 VAC
Line Regulation
⢠±0.5% maximum
Load Regulation
⢠See table
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠2% max pk-pk (see note 1)
Overvoltage Protection ⢠110-140% Vnom, recycle input to reset
Overtemperature
Protection
⢠Unit shuts down, recycle input to reset
Overload Protection ⢠110-150%, auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠88% min
⢠3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
⢠20-80 kHz variable
⢠5.1 W/In3
⢠>100 kHrs per MIL-HDBK-217F
(+25 °C ambient at full load)
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate from 100% power
at +40 °C to 60% power at +70 °C
Operating Humidity ⢠10-95% RH, non-condensing
Storage Temperature ⢠-20 °C to +80 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g, 10 ms on 3 axes
Vibration
⢠5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, ±15 kv contact and
air discharge
⢠EN61000-4-3, level 2 Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark
|
▷ |