English
Language : 

AMD150PS12 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
150 Watts
AMD150 Series
xppower.com
• Energy Star Level V
• CEC2008 & EISA2007 Compliant
• Universal Input
• High Efficiency
• 0 °C to +70 °C Operating Temperature
• Non-standard Connectors Available
• International Safety Approvals
Specification
Input
Input Voltage
• 90-264 VAC
Input Frequency
• 47-63 Hz
Input Current
• 2.0 A rms at 115 VAC,
1.0 A rms at 230 VAC
Inrush Current
• 60 A at 115 VAC, 120 A at 230 VAC,
cold start +25 °C
Power Factor
• 0.95 typical
Earth Leakage Current • 150 µA max at 115 VAC,
250 µA max at 230 VAC
No Load Input Power • <0.5 W
Output
Output Voltage
• See table
Output Voltage Trim • Not user-adjustable
Initial Set Accuracy • ±2%
Minimum Load
• No minimum load required
Start Up Delay
• 5 s max at 100 VAC
Hold Up Time
• 3 ms minimum at 100 VAC
Line Regulation
• ±0.5% maximum
Load Regulation
• See table
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% max pk-pk (see note 1)
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, recycle input to reset
Overload Protection • 110-150%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 88% min
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output 0 V is electrically connected to
Input Ground
• 20-80 kHz variable
• 5.1 W/In3
• >100 kHrs per MIL-HDBK-217F
(+25 °C ambient at full load)
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 60% power at +70 °C
Operating Humidity • 10-95% RH, non-condensing
Storage Temperature • -20 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• 30 g, 10 ms on 3 axes
Vibration
• 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022/FCC/VCCI, Class B conducted
EN55022/FCC/VCCI, Class B radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, ±15 kv contact and
air discharge
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
• EN60950, UL60950,
CSA22.2 No. 60950 per cUL, CE Mark