AFE220 Datasheet, PDF (1/2 Pages) XP Power Limited – Energy Efficiency Level V | |||
|
220 Watts
AFE220 Series
xppower.com
⢠Energy Efficiency Level V
⢠CEC2008, EISA2007 & ErP Compliant
⢠High Power Density
⢠Single Outputs from 12 V to 48 V
⢠High Efficiency
⢠Low Earth Leakage Current
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
Standby Power
Consumption
⢠90-264 VAC
⢠47-63 Hz
⢠2.1 A rms at 115 VAC,
1.1 A rms at 230 VAC
⢠110 A typical at 115 VAC,
cold start +25 °C
⢠0.95 typical at full load, 230 VAC
⢠400 µA max at 264 VAC, 60 Hz
⢠Internal T4 A/250 V fuse
⢠<0.5 W
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠Not user-adjustable
Initial Set Accuracy ⢠±2% maximum at 100% load
Minimum Load
⢠No minimum load required
Start Up Delay
⢠3 s maximum at 100 VAC
Hold Up Time
⢠5 ms minimum at 100 VAC
Line Regulation
⢠±0.5% maximum
Load Regulation
⢠See table
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠2% max pk-pk (see note 1)
Overvoltage Protection ⢠110-140% Vnom, recycle input to reset
Overtemperature
Protection
⢠Unit shuts down, auto recovery
Overload Protection ⢠110-150%, auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.04%/°C maximum
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠See table
⢠Level V
⢠3000 VAC Input to Output
1500 VAC Input to Ground
Output return is electrically connected to
Input Earth
⢠PFC: 40 kHz typical
PWM: 120-160 kHz
⢠5.0 W/In3
⢠>100 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature ⢠0 °C to 60 °C, derate from 100% power at
40 °C to 50% power at 60 °C
Operating Humidity ⢠10-95% RH, non-condensing
Storage Temperature ⢠-20 °C to +80 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g, 10 ms on 3 axes
Vibration
⢠5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, Class B conducted
EN55022, Class B radiated
⢠EN61000-3-2, Class A
⢠EN61000-3-3
⢠EN61000-4-2, ±8 kV contact,
±15 kV air discharge Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, installation class 3
Perf Criteria A
⢠EN61000-4-6, 3 Vrms Perf Criteria A
⢠EN61000-4-8, 1 A/m Perf Criteria A
⢠EN55024, 100% for 10 ms,
30% 500 ms, 100% 5000 ms,
Perf Criteria A, A, B High line,
A,B,B Low line
⢠EN60950-1, UL60950-1,
CSA22.2 No. 60950-1 per cUL, CE Mark
|
▷ |