English
Language : 

AEP06US042 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies
6-25 Watts
AEP Series
xppower.com
• Universal Input 90-264 VAC
• Interchangeable Mains Plug, 10 Watt Models
• Continous Short Circuit Protection
• EN550022 Class B
• Low Cost
• 6, 10, 15 and 25 Watt Versions
• Non-standard Outputs Available
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
• 90-264 VAC
• 47-63 Hz
• 0.2/0.09 A at 115/230 VAC (6W & 10W)
0.3/0.15 A at 115/230 VAC (15W)
0.5/0.3 A at 115/230 VAC (25W)
• 15/30 A max at 115/230 VAC (6W & 10W)
25/50 A max at 115/230 VAC (15W & 25W)
Output
Output Voltage
• See tables
Initial Set Accuracy • See tables
Minimum Load
• No minimum load requirement
Start Up Delay
• 6 W 100 ms,
10 W 240 ms,
15 W 270 ms,
25 W 280 ms
Hold Up Time
• 10 ms typical at 115 VAC,
60 ms typical at 230 VAC
Line Regulation
• See tables
Load Regulation
• See tables
Ripple & Noise
• 1 % pk-pk max (see note 2)
Overvoltage Protection • 125% typical
Overload Protection • Trip and restart (Hiccup mode)
Short Circuit Protection • Continuous (auto recovery)
General
Efficiency
Isolation
Switching Frequency
MTBF
• Typically 70% for 6 W,
75% for 10 and 15 W,
80% for 25 W
• 3000 VAC Input to Output
• 60 kHz ± 10 kHz
• >230 kHrs, MIL-HDBK-217F
Environmental
Operating Temperature • 0 ˚C to +40 ˚C
Storage Temperature • -20 ˚C to +85 ˚C
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, level B
• EN61000-4-2, level 2 Perf Criteria B
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, level 2 Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria B
• EN61000-4-11, 5 % UT 10 ms, Perf
Criteria B, 70 % UT 500 ms,
Perf Criteria C
• EN60950, UL1950,
CSA C22.2 No.234 cUL