English
Language : 

AEP Datasheet, PDF (1/3 Pages) Panasonic Battery Group – EP RELAYS
6 25 Watts
AEP Series
xppower.com
• Universal Input 90 264 VAC
• Continous Short Circuit Protection
• EN550022 Class B
• Low Cost
• 6, 15 and 25 Watt Versions
• Non standard Outputs Available
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
• 90-264 VAC
• 47-63 Hz
• 0.5/0.25 A max at 115/230 VAC (6 W & 15 W)
0.7/0.3 A at 115/230 VAC (25 W)
• 15/30 A max at 115/230 VAC (6 W)
25/50 A max at 115/230 VAC (15 W & 25 W)
• Meets EN61000-3-2, Class A
Output
Output Voltage
• See tables
Initial Set Accuracy • See tables
Minimum Load
• No minimum load requirement
Start Up Delay
• 6 W 100 ms,
15 W 270 ms,
25 W 280 ms
Hold Up Time
• 10 ms typical at 115 VAC,
60 ms typical at 230 VAC
Line Regulation
• See tables
Load Regulation
• See tables
Ripple & Noise
• 1 % pk-pk max (see note 2)
Overvoltage Protection • 125% typical
Overload Protection • Trip and restart (Hiccup mode)
Short Circuit Protection • Constant current (6 W)
Continuous (auto recovery) (15 W & 25 W)
Temp. Coefficient
• ±0.05%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• Typically 67% for 6 W,
75% for 15 W,
80% for 25 W
• 3000 VAC Input to Output
• 30-200 kHz (6 W)
30-35 kHz typical (15 W & 25 W)
• 0.75 W/in3 (6W), 1.87 W/in3 (15 W)
1.88 W/in3 (25 W)
• >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +60 °C, derate linearly from +40 °C
at 100% load to 60% load at +60 °C (6 W
& AEP15 5 V-13.6 V), 50% load at 60 °C
(25 W & AEP15 15 V-24 V)
Storage Temperature • -20 ˚ C to +85 ˚ C
Operating Humidity • 93% RH, non-condensing
Operating Altitude
• 2000 m
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
• EN55022 Class B conducted and radiated
• EN61000-3-2 Class A
• EN61000-3-3
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN61000-4-2, level 2 Perf Criteria B
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, Installation Class 2,
Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria B
• EN61000-4-11, 5 % UT 10 ms, Perf
Criteria B, 70 % UT 500 ms,
Perf Criteria C
• EN60950, UL1950,
CSA C22.2 No.234 cUL