English
Language : 

AEL15US03 Datasheet, PDF (1/8 Pages) XP Power Limited – AC-DC Power Supplies
15 Watts
AEL Series
xppower.com
• CEC 2008 & EISA 2007 Compliant
• Approved as LPS
• China Compulsory Certfication (CCC) Qualified
• High Efficiency
• +70 °C Operating Temperature
• Compact Dimensions
• Optional Input Connector
Specification
Input
Input Voltage
• 90-264 VAC
Input Frequency
• 47-63 Hz
Input Current
• 0.4 A at 115 VAC
Inrush Current
• 15 A/30 A for 115 VAC/230 VAC, cold start
Earth Leakage Current • 0.75 mA at 240 VAC
Power Factor
• Meets EN61000-3-2
Input Protection
• Fitted with internal fuse
Standby Power
Consumption
• Typically 0.3 W, max 0.5 W
Output
Output Voltage
• See tables
Minimum Load
• No minimum load required
Hold Up Time
• 5 ms min at full load 110 VAC
Start Up Delay
• 2.0 s at full load 100 VAC
Transient Response
• 2% deviation, recovery to within 1% of
nominal in 4 ms for 50% load change
Line Regulation
• See tables
Load Regulation
• See tables
Ripple & Noise
• 1% pk-pk max, 20 MHz BW. See note 3.
Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery
Temperature
Coefficient
• ±0.04%/°C
General
Efficiency
Isolation
Switching Frequency
MTBF
• 85% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 63 kHz typical
• 300 kHrs to MIL-STD-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature • -40 °C to +85 °C
Cooling
• Convection cooled
Operating Humidity • 5-95% RH, non-condensing
Operating Altitude
• 3000 m
Shock
• 10 g, 10 ms on 3 axes
Vibration
• 5-100 Hz 2.31 m/s2, 20 mins 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 FCC Part-15C Level B
conducted & radiated
• EN61000-3-2 Class A
• EN61000-3-3
• EN61000-4-2 Level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 Level 2 Perf criteria A
• EN61000-4-5 Level 3 Perf criteria A
• EN61000-4-6 Level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
• EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
• EN60950-1:2001, UL/cUL60950-1,
Approved as Limited Power Source,
CE Mark, China Compulsory Certification
(CCC) qualified.