AEL15US03 Datasheet, PDF (1/8 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
15 Watts
AEL Series
xppower.com
⢠CEC 2008 & EISA 2007 Compliant
⢠Approved as LPS
⢠China Compulsory Certfication (CCC) Qualified
⢠High Efficiency
⢠+70 °C Operating Temperature
⢠Compact Dimensions
⢠Optional Input Connector
Specification
Input
Input Voltage
⢠90-264 VAC
Input Frequency
⢠47-63 Hz
Input Current
⢠0.4 A at 115 VAC
Inrush Current
⢠15 A/30 A for 115 VAC/230 VAC, cold start
Earth Leakage Current ⢠0.75 mA at 240 VAC
Power Factor
⢠Meets EN61000-3-2
Input Protection
⢠Fitted with internal fuse
Standby Power
Consumption
⢠Typically 0.3 W, max 0.5 W
Output
Output Voltage
⢠See tables
Minimum Load
⢠No minimum load required
Hold Up Time
⢠5 ms min at full load 110 VAC
Start Up Delay
⢠2.0 s at full load 100 VAC
Transient Response
⢠2% deviation, recovery to within 1% of
nominal in 4 ms for 50% load change
Line Regulation
⢠See tables
Load Regulation
⢠See tables
Ripple & Noise
⢠1% pk-pk max, 20 MHz BW. See note 3.
Short Circuit Protection ⢠Trip & restart (Hiccup mode), auto recovery
Temperature
Coefficient
⢠±0.04%/°C
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠85% typical
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
⢠63 kHz typical
⢠300 kHrs to MIL-STD-217F
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature ⢠-40 °C to +85 °C
Cooling
⢠Convection cooled
Operating Humidity ⢠5-95% RH, non-condensing
Operating Altitude
⢠3000 m
Shock
⢠10 g, 10 ms on 3 axes
Vibration
⢠5-100 Hz 2.31 m/s2, 20 mins 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 FCC Part-15C Level B
conducted & radiated
⢠EN61000-3-2 Class A
⢠EN61000-3-3
⢠EN61000-4-2 Level 3 Perf criteria A
⢠EN61000-4-3 3 V/m Perf criteria A
⢠EN61000-4-4 Level 2 Perf criteria A
⢠EN61000-4-5 Level 3 Perf criteria A
⢠EN61000-4-6 Level 2 Perf criteria A
⢠EN61000-4-8 1 A/m Perf criteria A
⢠EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
⢠EN60950-1:2001, UL/cUL60950-1,
Approved as Limited Power Source,
CE Mark, China Compulsory Certification
(CCC) qualified.
|
▷ |