AEL Datasheet, PDF (1/6 Pages) XP Power Limited – Energy Efficiency Level V
15 80 Watts
AEL Series
xppower.com
• Energy Efficiency Level V
• CEC 2008 and EISA 2007 Compliant
• Limited Power Source Approval
• China Compulsory Certification (CCC) Qualified
• +60 °C Operating Temperature
• Compact Dimensions
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
Input Protection
No Load Input Power
• 90-264 VAC
• 47-63 Hz
• AEL15/20: 0.4 A max at 115 VAC
AEL40: 1.0 A max at 115 VAC
AEL60: 1.6 A max at 115 VAC
AEL80: 1.1 A max at 115 VAC
• AEL15/20: 15/30 A max for 115/230 VAC,
AEL40: 25/50 A max for 115/230 VAC,
AEL60: 35/70 A max for 115/230 VAC,
AEL80: 45/92 A max for 115/230 VAC,
cold start at 25 °C
• 0.75 mA at 240 VAC
• EN61000-3-2, Class A
• Internal fuse in line,
AEL15/20: T1 A, 250 V
AEL40: T2 A, 250 V
AEL60/80: T3.15 A, 250 V
• 0.5 W maximum, model dependent
Output
Output Voltage
• See tables
Minimum Load
• No minimum load required
Hold Up Time
• AEL15: 5 ms min, AEL20/40: 12 ms min,
AEL60/80: 16 ms min, at full load
110 VAC
Start Up Delay
• AEL20/40: 0.5 s, AEL15/60/80: 2.0 s
max at full load 100 VAC
Transient Response
• 2% max deviation, recovery to within 1%
of nominal in 500 µs for 50% load change
Line Regulation
• See tables
Load Regulation
• See tables
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection • 112-132% (AEL40/60/80 only)
Overload Protection • 110-150% (AEL20/40/60/80 only)
Short Circuit Protection • Trip & restart (hiccup mode),
auto recovery
Temperature
Coefficient
• ±0.04%/°C
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
• See tables
• Model dependent, see tables
• 3000 VAC Input to Output
1500 VAC Input to Ground*
500 VDC Output to Ground*
*Not C8 version
All class I models available with output
negative connected to ground. See notes.
• 63 kHz typical
• >100 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • -20 °C to +60 °C, derate linearly from
100% power at +40 °C to 50% power at
+60 °C
Storage Temperature • -40 °C to +85 °C
Cooling
• Convection cooled
Operating Humidity • 5-95% RH, non-condensing
Operating Altitude
• 2000 m
Shock
• 10 g, 10 ms on 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022 level B conducted & radiated
• EN61000-3-2 class A
• EN61000-3-3
• EN61000-4-2 Level 2 (contact) Perf Criteria A
EN61000-4-2 Level 3 (air) Perf Criteria A
• EN61000-4-3, 3 V/m, Perf criteria A
• EN61000-4-4, level 2, Perf criteria A
• EN61000-4-5, installation class 3,
Perf criteria A
• EN61000-4-6, level 2, Perf criteria A
• EN61000-4-8, 1 A/m, Perf criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• EN60950-1: UL/cUL60950-1,
Approved as Limited Power Source
(AEL15-60 only), China Compulsory
Certification (CCC) qualified.