AEL Datasheet, PDF (1/6 Pages) XP Power Limited – Energy Efficiency Level V | |||
|
15 80 Watts
AEL Series
xppower.com
⢠Energy Efficiency Level V
⢠CEC 2008 and EISA 2007 Compliant
⢠Limited Power Source Approval
⢠China Compulsory Certification (CCC) Qualified
⢠+60 °C Operating Temperature
⢠Compact Dimensions
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
Input Protection
No Load Input Power
⢠90-264 VAC
⢠47-63 Hz
⢠AEL15/20: 0.4 A max at 115 VAC
AEL40: 1.0 A max at 115 VAC
AEL60: 1.6 A max at 115 VAC
AEL80: 1.1 A max at 115 VAC
⢠AEL15/20: 15/30 A max for 115/230 VAC,
AEL40: 25/50 A max for 115/230 VAC,
AEL60: 35/70 A max for 115/230 VAC,
AEL80: 45/92 A max for 115/230 VAC,
cold start at 25 °C
⢠0.75 mA at 240 VAC
⢠EN61000-3-2, Class A
⢠Internal fuse in line,
AEL15/20: T1 A, 250 V
AEL40: T2 A, 250 V
AEL60/80: T3.15 A, 250 V
⢠0.5 W maximum, model dependent
Output
Output Voltage
⢠See tables
Minimum Load
⢠No minimum load required
Hold Up Time
⢠AEL15: 5 ms min, AEL20/40: 12 ms min,
AEL60/80: 16 ms min, at full load
110 VAC
Start Up Delay
⢠AEL20/40: 0.5 s, AEL15/60/80: 2.0 s
max at full load 100 VAC
Transient Response
⢠2% max deviation, recovery to within 1%
of nominal in 500 µs for 50% load change
Line Regulation
⢠See tables
Load Regulation
⢠See tables
Ripple & Noise
⢠1% pk-pk, 20 MHz bandwidth
Overvoltage Protection ⢠112-132% (AEL40/60/80 only)
Overload Protection ⢠110-150% (AEL20/40/60/80 only)
Short Circuit Protection ⢠Trip & restart (hiccup mode),
auto recovery
Temperature
Coefficient
⢠±0.04%/°C
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
⢠See tables
⢠Model dependent, see tables
⢠3000 VAC Input to Output
1500 VAC Input to Ground*
500 VDC Output to Ground*
*Not C8 version
All class I models available with output
negative connected to ground. See notes.
⢠63 kHz typical
⢠>100 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature ⢠-20 °C to +60 °C, derate linearly from
100% power at +40 °C to 50% power at
+60 °C
Storage Temperature ⢠-40 °C to +85 °C
Cooling
⢠Convection cooled
Operating Humidity ⢠5-95% RH, non-condensing
Operating Altitude
⢠2000 m
Shock
⢠10 g, 10 ms on 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 level B conducted & radiated
⢠EN61000-3-2 class A
⢠EN61000-3-3
⢠EN61000-4-2 Level 2 (contact) Perf Criteria A
EN61000-4-2 Level 3 (air) Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf criteria A
⢠EN61000-4-4, level 2, Perf criteria A
⢠EN61000-4-5, installation class 3,
Perf criteria A
⢠EN61000-4-6, level 2, Perf criteria A
⢠EN61000-4-8, 1 A/m, Perf criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
⢠EN60950-1: UL/cUL60950-1,
Approved as Limited Power Source
(AEL15-60 only), China Compulsory
Certification (CCC) qualified.
|
▷ |