English
Language : 

AEH15US03 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
15-24 Watts
AEH Series
xppower.com
• Output Voltages from 3- 48 VDC Available
• Non-Standard Outputs
• Universal Input
• +70 ºC Operating Temperature
• High Efficiency - Up to 85%
• Class 1 Earthing
• Non-standard Connectors Available
Specification
Input
Input Voltage
• 90-264 VAC
Input Frequency
• 47-63 Hz
Input Current
• 0.4 A for AEH15, at 230 VAC
0.7 A for AEH24, at 230 VAC
Inrush Current
• 15/30 A max at 115/230 VAC 100% load,
cold start
Earth Leakage Current • <0.5 mA max at 115 VAC/60Hz
<0.75 mA max at 230 VAC/50Hz
Output
Output Voltage
• See tables (factory set). Non-standard
voltages available - contact sales
Initial Set Accuracy • 5%
Start Up Delay
• 2 s max
Hold Up Time
• 20 ms min at full load and 115 VAC
Line Regulation
• See tables
Load Regulation
• See tables
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 2% pk-pk, 20 MHz BW
Overvoltage Protection • 112-132% Vnom, auto reset
Overload Protection • 112-132% of nominal, auto recovery
Temperature
Coefficient
• ±0.04% /˚C max
General
Efficiency
Isolation
MTBF
• Up to 85%
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from
full load at +40 ˚C to half load at +70 ˚C
Operating Humidity • 5-95 % RH, non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 level B, conducted and radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950, UL60950,
CSA C22.2 No. 950 per cUL,
UL60950