English
Language : 

AEH Datasheet, PDF (1/5 Pages) XP Power Limited – Output Voltages from 2.5 V to 48 V
15-130 Watts
AEH Series
xppower.com
• Output Voltages from 2.5 V to 48 V
• Non-standard Outputs Available
• Universal Input
• Single & Multiple Output Versions
• 0 °C to +60 °C Operating Temperature
• Efficiency up to 80%
• Non-standard Connectors Available
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
• 90-264 VAC
• 47-63 Hz
• 0.4/0.26 A for AEH15, at 115/230 VAC
1.5/0.7 A for AEH45, at 115/230 VAC
1.9/1.5 A for AEH80, at 115/230 VAC
3.2/1.7 A for AEH130, at 115/230 VAC
• AEH15, 45 & 80: 30 A max at 230 VAC
AEH130: 60 A max at 230 VAC
cold start
• <0.5 mA max at 115 VAC/60 Hz
<0.75 mA max at 230 VAC/50 Hz
• EN61000-3-2 class A
Output
Output Voltage
• See tables, non-standard voltages
available - contact sales
Initial Set Accuracy • 5%
Start Up Delay
• 2 s max
Hold Up Time
• 16 ms min (>50 ms AEH130)
Line Regulation
• See tables
Load Regulation
• See tables
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 2% pk-pk for outputs ≤3.3 V
1% pk-pk for all other outputs
20 MHz bandwidth
Overvoltage Protection • 112-132% Vnom, auto reset
Overload Protection
• Output 1 only 110-150% of nominal
(AEH15 Output protected to short circuit)
Temperature
Coefficient
• ±0.04%/°C max
General
Efficiency
Isolation
Switching Frequency
MTBF
• Up to 80%
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 65-80 kHz for AEH15
67-83 kHz for AEH45
58 kHz typical for AEH80
53-76 kHz for AEH130
• 100 kHrs per MIL-HDBK-217F at 25 °C GB
Environmental
Operating Temperature • 0 °C to +60 °C, derate linearly from 100%
load at +40 °C to 50% load at +60 °C
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 level B, conducted and radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA C22.2 No. 950 per cUL, CE Mark