AED36US05 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
36-100 Watts
AED Series
xppower.com
⢠Low Profile
⢠Single Outputs from 5 V to 48 V
⢠Universal Input
⢠Optional Floating Output
⢠High Power Density
⢠36, 45, 70 & 100 W Versions
⢠Class II Insulation on 36 W Version
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
⢠90-264 VAC
⢠47-63 Hz
⢠AED36: 1.00 A max
AED45: 1.20 A max
AED70: 1.85 A max
AED100: 2.00 A max
⢠AED36: 50 A max at 230 VAC
AED45: 100 A max at 230 VAC
AED70: 100 A max at 230 VAC
AED100: 100 A max at 230 VAC
⢠AED36: Class II
AED45: 1.5 mA max
AED70: 1.5 mA max
AED100: 1.5 mA max
⢠Compliant with EN61000-3-2
Output
Output Voltage
⢠See tables
Initial Set Accuracy ⢠±2%
Minimum Load
⢠No minimum load requirement
Hold Up Time
⢠AED36: 8 ms min at 115 VAC
AED45: 8 ms min at 115 VAC
AED70: 8 ms min at 115 VAC
AED100: 20 ms typical at 115 VAC
Line Regulation
⢠±1%
Load Regulation
⢠See tables
Ripple & Noise
⢠1% pk-pk max, 20 MHz BW (see note 2)
Overvoltage Protection ⢠Typical 125% max
Overload Protection
⢠120-150% hiccup/trip & restart mode
with auto recovery
Short Circuit Protection ⢠Continuous
Temperature
Coefficient
⢠±0.04%/ËC
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠85% typical at 230 VAC & 100% load
⢠3000 VAC Input to Output,
1500 VAC Input to Ground.
Negative output is connected to ground.
For optional 500 VAC output to ground
isolation add suffix â-Fâ to model number
⢠60 kHz ±10 kHz
⢠100,000 Hrs to MIL-HDBK-217E
Environmental
Operating Temperature ⢠0 ËC to +65 ËC
AED36, AED45 & AED70 derate
linearly from 100% load at +40 ËC to
50% load at +55 ËC,
AED100 derate linearly from
100% load at +40 ËC to 0% at +65 ËC
Storage Temperature ⢠-20 ËC to +85 ËC
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Safety Approvals
⢠CISPR22 Level B (EN55022)
FCC 20780 Level B
⢠EN61000-4-2,
8 kV air
4 kV contact
Perf Criteria A
⢠EN61000-4-3, 3 V/m
Perf Criteria A
⢠EN61000-4-4, level 2
Perf Criteria A
⢠EN60950-1, UL60950-1,
CAN/CSA C22.2 No. 60950 cUL
|
▷ |