AED Datasheet, PDF (1/4 Pages) Emerson Network Power – Industry standard package 16th Brick 0.90” x 1.30
36 70 Watts
AED Series
xppower.com
• Low Profile
• Single Outputs from 5 V to 48 V
• Universal Input
• Optional Floating Output
• High Power Density
• Class II Insulation on 36 W Version
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
• 90-264 VAC
• 47-63 Hz
• AED36: 1.00 A max
AED45: 1.20 A max
AED70: 2.00 A max
• AED36: 50 A max at 230 VAC
AED45: 100 A max at 230 VAC
AED70: 100 A max at 240 VAC
• AED36: Class II
AED45/70: 3.5 mA max
• Compliant with EN61000-3-2
Output
Output Voltage
• See tables
Initial Set Accuracy • ±2%
Minimum Load
• No minimum load requirement
Hold Up Time
• AED36: 8 ms min at 115 VAC
AED45: 8 ms min at 115 VAC
AED70: 20 ms min at 115 VAC
Line Regulation
• ±1%
Load Regulation
• See tables
Ripple & Noise
• 1% pk-pk max, 20 MHz BW (see note 2)
Overvoltage Protection • Typical 125% max
Overload Protection
• 120-150% hiccup/trip & restart mode
with auto recovery
Short Circuit Protection • Continuous
Temperature
Coefficient
• ±0.05%/˚C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
• 85% typical at 230 VAC & 100% load
• 3000 VAC Input to Output,
1500 VAC Input to Ground.
Negative output is connected to ground.
For optional 500 VAC output to ground
isolation add suffix ‘-F’ to model number
• 60 kHz ±10 kHz
• AED36: 5.34 W/in3
AED45: 3.20 W/in3
AED70: 4.98 W/in3
• 200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 ˚C to +60 ˚C derate linearly from 100%
load at +40 ˚C to 50% load at +60 ˚C
Operating Humidity • 93% RH, non-condensing
Operating Altitude
• 2000 m
Storage Temperature • -20 ˚C to +85 ˚C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Safety Approvals
• EN55022 Class B conducted & radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, 8 kV air, 4 kV contact
Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN60950-1, UL60950-1