English
Language : 

ACM06 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies
ACM06 Series
AC-DC Power Supplies
6 Watt
xxx Series • Energy Efficiency Level VI
• European CoC Tier 2
• Medical and ITE Approvals
• Interchangeable Mains Connectors
• Optional White Versions
• Output Voltages from 5 V to 12 V
• Class II Construction
• 3 Years Warranty
The ACM06 series of wall plug adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector as well as USB versions, these adaptors suit a wide variety of cost
sensitive industrial and medical applications while maintaining industry leading performance.
Dimensions:
ACM (body only):
2.89 x 1.21 x 1.67” (73.5 x 30.7 x 42.5 mm)
Models & Ratings
Output Power
6W
Output Voltage
5.0 V
9.0 V
12.0 V
Output Current
1000 mA
600 mA
500 mA
Notes
1. Model number is for body only. AC input plugs must be ordered separately, see
AC input plug section.
2. Other output voltages available, contact sales for details.
3. Total regulation includes initial set accuracy, line and load regulation.
4. Typical average value measured at 115 VAC.
Total Regulation(3)
5%
5%
5%
Efficiency(4)
82.5%
86.7%
87.5%
Model Number(1,2,5)
ACM06US05(6)
ACM06US09
ACM06US12
5. For white case version add suffix ‘-W’ e.g. ACM06US12-W. MOQ applies, contact
sales for details.
6. For 5 V version with optional USB type A connector in case, add suffix -BB,
e.g ACM06US05-BB.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Minimum
90
47
Typical
Maximum
264
63
0.2
70
75
Internal fuse in both line and neutral
Units
VAC
Hz
A
A
mW
Notes & Conditions
100 VAC
240 VAC, cold start at 25 °C
EN61000-3-2, class A
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Transient Response
Ripple & Noise
Short Circuit Protection
Temperature Coefficient
Minimum
5
0
10
Typical
30
Maximum
12
4
5
4
150
0.05
Units
V
A
s
ms
ms
%
% deviation
mV pk-pk
%/ ˚C
Notes & Conditions
See Models and Ratings table
No minimum load required
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Measured with 20 MHz bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Continuous, trip and restart (hiccup mode) with auto recovery
1