ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ................................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
70°C
+85°C
+125°C
3840 PGM T09
Supply Voltage
X24C16
X24C16–3.5
X24C16–3
X24C16–2.7
Limits
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7V to 5.5V
3840 PGM T10
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified)
Symbol
Parameter
Limits
Min.
Max.
Units
Test Conditions
lCC1
VCC Supply Current (read)
1
SCL = VCC x 0.1/VCC x 0.9 Levels
lCC2
VCC Supply Current (write)
3
mA @ 100 KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
ISB1(1) VCC Standby Current
150
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
ISB2(1) VCC Standby Current
50
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 3.3V +10%
ILI
Input Leakage Current
10
µA VIN = GND to VCC
ILO
Output Leakage Current
10
µA VOUT = GND to VCC
VlL(2) Input Low Voltage
–1.0 VCC x 0.3 V
VIH(2) Input High Voltage
VCC x 0.7 VCC + 0.5 V
VOL
Output Low Voltage
0.4
V IOL = 3 mA
CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V
3840 PGM T03
Symbol
Parameter
Max. Units
Test Conditions
CI/O(3)
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL)
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
8
pF
6
pF
VI/O = 0V
VIN = 0V
3840 PGM T05
9