English
Language : 

X24C08 Datasheet, PDF (9/16 Pages) Xicor Inc. – Serial E2PROM
X24C08
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias ................. –65°C to +135°C
Storage Temperature ...................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ................................. –1.0V to +7V
D.C. Output Current ........................................... 5 mA
Lead Temperature
(Soldering, 10 Seconds) .............................. 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Military
Min.
0°C
–40°C
–55°C
Max.
70°C
+85°C
+125°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Supply Voltage
X24C08
X24C08-3.5
X24C08-3
X24C08-2.7
Limits
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over recommneded operating conditions, unless otherwise specified.)
Symbol
Parameter
Limits
Min.
Max.
Units
Test Conditions
lCC1 VCC Supply Current (Read)
1
lCC2 VCC Supply Current (Write)
3
ISB1(1) VCC Standby Current
150
ISB2(1) VCC Standby Current
50
ILI
ILO
VlL(2)
VIH(2)
VOL
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
10
10
–1.0 VCC x 0.3
VCC x 0.7 VCC + 0.5
0.4
CAPACITANCE TA = 25°C, F = 1.0MHZ, VCC = 5V
Symbol
Test
SCL = VCC x 0.1/VCC x 0.9 Levels @ 100
KHz, SDA = Open,
mA All Other Inputs = GND or VCC – 0.3V
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 3V
µA VIN = GND to VCC
µA VOUT = GND to VCC
V
V
V IOL = 3 mA
3842 PGM T02
Max.
Units
Conditions
CI/O(3)
Input/Output Capacitance (SDA)
8
pF
CIN(3)
Input Capacitance (A0, A1, A2, SCL)
6
pF
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min and VIH max. are for reference only and are not 100% tested.
(3) This parameter is periodically sampled and not 100% tested.
VI/O = 0V
VIN = 0V
3842 PGM T04
9