English
Language : 

X24164 Datasheet, PDF (9/14 Pages) Xicor Inc. – Serial E2PROM
X24164
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias
X24164 ...................................... –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ................................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature (Soldering, 10 Seconds) ..... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
0°C
70°C
X24164
4.5V to 5.5V
Industrial
–40°C
+85°C
X24164-3
3V to 5.5V
Military
–55°C
+125°C
X24164-2.7
2.7V to 5.5V
3846 PGM T02
3846 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
ICC1
Other
ICC2
ISB1(1)
ISB2(1)
ILI
ILO
VlL(2)
VIH(2)
VOL
Parameter
VCC Supply Current (Read)
Limits
Min.
Max.
1
Units
Test Conditions
mA SCL = VCC X 0.1/VCC X 0.9 Levels
@ 100 KHz, SDA = Open, All
VCC Supply Current (Write)
VCC Standby Current
VCC Standby Current
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
3
mA
150
µA
50
µA
10
µA
10
µA
–1.0 VCC x 0.3 V
VCC x 0.7 VCC + 0.5 V
0.4
V
Inputs = GND or VCC – 0.3V
SCL = SDA = VCC, All Other
Inputs = GND or VCC – 0.3V,
VCC = 5V ± 10%
SCL = SDA = VCC, All Other
Inputs = GND or VCC – 0.3V,
VCC = 3V
VIN = GND to VCC
VOUT = GND to VCC
IOL = 3 mA
3846 PGM T04
CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V
Symbol
Parameter
CI/O(3)
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (S0, S1, S2, SCL)
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not 100% tested.
(3) This parameter is periodically sampled and not 100% tested.
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
3846 PGM T05
9