English
Language : 

X24012 Datasheet, PDF (9/14 Pages) Xicor Inc. – Serial E2PROM
X24012
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ............................... –1.0V to +7V
D.C. Output Current ............................................ 5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
0°C
70°C
X24012
4.5V to 5.5V
Industrial
–40°C
+85°C
X24012-3
3V to 5.5V
Military
–55°C
+125°C
X24012-2.7
2.7V to 5.5V
3847 PGM T02
3847 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
Parameter
Limits
Min.
Max.
Units
Test Conditions
lCC1 Power Supply Current (Read)
1
mA SCL = VCC x 0.1/VCC x 0.9 Levels @
100 KHz, SDA = Open, All Other
lCC2 Power Supply Current (Write)
2
Inputs = GND or VCC – 0.3V
ISB(1) Standby Current
50
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
ISB(2) Standby Current
30
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC= 3V
ILI
Input Leakage Current
10
µA VIN = GND to VCC
ILO Output Leakage Current
10
µA VOUT = GND to VCC
VlL(2) Input Low Voltage
–1.0 VCC x 0.3 V
VIH(2) Input High Voltage
VCC x 0.7 VCC + 0.5 V
VOL Output Low Voltage
0.4
V IOL = 3 mA
3847 PGM T04
CAPACITANCE TA = 25°C, F = 1.0MHZ, VCC = 5V
Symbol
Test
Max.
Units
Conditions
CI/O(3)
Input/Output Capacitance (SDA)
8
pF
CIN(3)
Input Capacitance (A0, A1, A2, SCL, WC)
6
pF
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
VI/O = 0V
VIN = 0V
3847 PGM T06