English
Language : 

X76F102 Datasheet, PDF (8/18 Pages) Xicor Inc. – The X76F102 is a Password Access Security Supervisor, containing one 896-bit Secure SerialFlash array
X76F102
RECOMMENDED OPERATING CONDITIONS
Temp
Min.
Max.
Commercial
0°C
+70°C
Industrial
–40°C
+85°C
Supply Voltage
X76F102
X76F102 – 2
Limits
4.5V to 5.5V
2.0V to 5.5V
7025 FM T06
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC1
VCC Supply Current
(Read)
ICC2(3)
VCC Supply Current
(Write)
ISB1(1)
ISB2(1)
ILI
ILO
VIL(2)
VIH(2)
VOL
VCC Supply Current
(Standby)
VCC Supply Current
(Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Limits
Min.
Max. Units
Test Conditions
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 KHz,
1
mA SDA = Open
RST = VSS
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 KHz,
3
mA SDA = Open
RST = VSS
1
µA
VIL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 400 KHz, fSDA = 400 KHz
1
µA VSDA = VSCC = VCC
Other = GND or VCC–0.3V
10
µA VIN = VSS to VCC
10
µA VOUT = VSS to VCC
–0.5 VCC x 0.1 V
VCC x 0.9 VCC + 0.5 V
0.4
V IOL = 3mA
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
COUT(3)
CIN(3)
Test
Output Capacitance (SDA)
Input Capacitance (RST, SCL)
Max.
8
6
Units
pF
pF
NOTES:(1) Must perform a stop command after a read command prior to measurement
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
Conditions
VI/O = 0V
VIN = 0V
EQUIVALENT A.C. LOAD CIRCUIT
OUTPUT
5V
1.53KW
OUTPUT
100pF
3V
1.3KW
100pF
A.C. TEST CONDITIONS
Input Pulse Levels
Input Rise and Fall Times
Input and Output Timing
Level
Output Load
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
100pF
8