English
Language : 

X84041 Datasheet, PDF (7/13 Pages) Xicor Inc. – Micro Port Saver E2PROM
X84041
EQUIVALENT A.C. LOAD CIRCUITS
5V
2.06KΩ
OUTPUT
3.03KΩ
30pF
3V
2.39KΩ
OUTPUT
4.58KΩ
30pF
2704 ILL F05.2
2704 ILL F05a.3
A.C. CHARACTERISTICS
(Over the recommended operating conditions, unless otherwise specified.)
Read Cycle Limits – X84041
Symbol Parameter
VCC = 5V ±10%
Min.
Max.
VCC = 3V ±10%
Min.
Max.
tRC
Read Cycle Time
300
tCE
CE Access Time
45
tOE
OE Access Time
45
tLOW
CE LOW Time
70
tHIGH
CE HIGH Time
70
tLZ(4)
CE LOW to Output In Low Z
0
tHZ(4)
CE HIGH to Output In High Z
0
30
tOLZ(4)
OE LOW to Output In Low Z
0
tOHZ(4) OE HIGH to Output In High Z
0
30
tOH
Output Hold from CE or OE HIGH
0
tWES
WE HIGH Setup Time
25
tWEH
WE HIGH Hold Time
25
300
65
65
70
70
0
0
35
0
0
35
0
25
25
Notes: (4) Periodically sampled, but not 100% tested. tHZ and tOHZ are measured from the point where CE or OE goes
HIGH (whichever occurs first) to the time when I/O is no longer being driven into a 5pF load.
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
2704 PGM T09.3
7