X25F087
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
7007 FRM T04
Supply Voltage
X25F087
X25F087-5
Limits
1.8V to 3.6V
4.5V to 5.5V
7007 FRM T05
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max. Units
Test Conditions
ICC1
ICC2
ISB
ILI
ILO
VIL(1)
VIH(1)
VOL1
VOH1
VOL2
VOH2
VOL3
VOH3
VCC Read Current (Active)
1
mA SCK = VCC x 0.1/VCC x 0.9 @ 1MHz,
SO = Open, CS = VSS
VCC Write Current (Active)
3
mA SCK = VCC x 0.1/VCC x 0.9 @ 1MHz,
SO = Open, CS = VSS
VCC Supply Current (Standby)
1
µA CS = VCC - 0.1, VIN = VSS or VCC
Input Leakage Current
10
µA VIN = VSS to VCC
Output Leakage Current
10
µA VOUT = VSS to VCC
Input LOW Voltage
–0.5 VCC x 0.3 V
Input HIGH Voltage
VCC x 0.7 VCC + 0.5 V
Output LOW Voltage
0.4
V VCC = 5.5V, IOL = 2.1mA
Output HIGH Voltage
VCC – 0.8
V VCC = 5.5V, IOH = –1.0mA
Output LOW Voltage
0.4
V VCC = 3.6V, IOL = 1.0mA
Output HIGH Voltage
VCC – 0.4
V VCC = 3.6V, IOH = –0.4mA
Output LOW Voltage
0.4
V VCC = 1.8V, IOL = 0.5mA
Output HIGH Voltage
VCC – 0.2
V VCC = 1.8V, IOH = –0.25mA
POWER-UP TIMING
7007 FRM T06
Symbol
Parameter
Min.
Max.
Units
tPUR(3)
tPUW(3)
Power-up to Read Operation
Power-up to Write Operation
1
ms
5
ms
CAPACITANCE TA = +25°C, f = 1MHz, VCC =5V.
7007 FRM T07
Symbol
Parameter
Max.
Units
Conditions
COUT(2)
CIN(2)
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, PP)
8
pF
6
pF
VOUT = 0V
VIN = 0V
7007 FRM T08
Notes: (1) VIL Min. and VIH Max. are for reference only and are not 100% tested.
(2) This parameter is periodically sampled and not 100% tested.
(3) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
7