English
Language : 

X9511 Datasheet, PDF (6/10 Pages) Xicor Inc. – PushPot O Potentiometer (Push Button Controlled)
X9511
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min. Typ.(6) Max. Units
tGAP
tDB
tS SLOW
tS
(7)
FAST
tPU(7)
tR VCC(7)
tASTO(7)
VASTH(7)
VASEND(7)
Time Between Two Separate Push Button Events
Debounce Time
After Debounce to Wiper Change on a Slow Mode
Wiper Change on a Fast Mode
Power Up to Wiper Stable
VCC Power-up Rate
AUTOSTORE Cycle Time
AUTOSTORE Threshold Voltage
AUTOSTORE Cycle End Voltage
0
µs
30
60
ms
100
250
375
ms
25
50
75
ms
500
µs
0.2
50
mV/µs
2
ms
4
V
3.5
V
3067 FRM T07.3
AUTOSTORE Cycle Timing Diagram
5
VCC
VASTH
AUTOSTORE CYCLE IN PROGRESS
VASEND
tASTO
STORE TIME
TIME (ms)
Notes: VASTH – AUTOSTORE threshold voltage
VASEND – AUTOSTORE cycle end voltage
tASTO – AUTOSTORE cycle time
(6) Typical values are for TA = 25°C and nominal supply voltage.
(7) This parameter is periodically sampled and not 100% tested.
3067 ILL F04.2
6