X9319
A.C. OPERATING CHARACTERISTICS
(VCC = 5V ±10%, TA = Full Operating Temperature Range unless otherwise stated)
Limits
Symbol
Parameter
Min.
Typ.(4)
tCl
tlD(5)
tDI(5)
tlL
tlH
tlC
tCPHS
tCPHNS(5)
tIW(5)
tCYC
tR, tF(5)
tPU(5)
tR VCC(5)
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time (STORE)
CS deselect time (NO STORE)
INC to RW change
INC cycle time
INC input rise and fall time
Power up to wiper stable
VCC power-up rate
100
100
1
1
1
1
20
1
100
4
0.2
Max.
500
500
500
50
Unit
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
µs
V/ms
POWER UP AND DOWN REQUIREMENTS
In order to prevent unwanted tap position changes, or an inadvertant store, bring the CS and INC high before or
concurrently with the VCC pin on powerup. The potentiometer voltages must be applied after this sequence is com-
pleted. During power-up, the data sheet parameters for the DCP do not fully apply until 1 millisecond after VCC
reaches its final value. The VCC ramp spec is always in effect.
A.C. TIMING
CS
tCI
INC
U/D
tIW
RW
tCYC
tIL
tIH
tID
tIC
tDI
MI (3)
tCPHS
90% 90%
10%
tCPHNS
tF
tR
REV 1.7 7/10/03
www.xicor.com
5 of 10