X9316 Datasheet, PDF (5/12 Pages) Xicor Inc. – E 2 POT™ Nonvolatile Digital Potentiometer | |||
|
◁ |
X9316
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
â40°C
Max.
+70°C
+85°C
7000 FRM T02
Supply Voltage
X9316
Limits
5V ±10%
7000 FRM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Limits
Symbol
ICC
ISB
Parameter
VCC Active Current (Increment)
VCC Active Current (Store)
Standby Supply Current
IV+(5)
V+ Supply Current
IVâ(5)
Vâ Supply Current
ILI
CS, INC, U/D Input Leakage
Current
Min.
Typ.(4)
Max.
50
400
1
400
400
±10
Units
µA
µA
µA
µA
µA
µA
Test Conditions
CS = VIL, U/D = VIL or VIH and
INC = 0.4V/2.4V @ max. tCYC
CS = VCC â 0.3V, U/D and
INC = VSS or VCC â 0.3V
CS = VIL, U/D = VIL or VIH and
INC = 0.4V/2.4V @ max. tCYC
CS = VIL, U/D = VIL or VIH and
INC = 0.4V/2.4V @ max. tCYC
VIN = VSS to VCC
VIH
CS, INC, U/D Input HIGH
2
Voltage
VCC + 1 V
VIL
RW
VVH
VVL
V+
Vâ
CIN(5)
CS, INC, U/D Input LOW
â1
0.8
Voltage
Wiper Resistence
100
200
VH Terminal Voltage
Vâ
V+
VL Terminal Voltage
Vâ
V+
Analog Positive Power Supply
VCC
VCC
Analog Negative Power
âVCC
0
Supply
CS, INC, U/D Input
10
Capacitance
V
â¦
Max. Wiper Current ±1mA
V
V
V
V
pF
VCC = 5V, VIN = VSS, TA = 25°C
7000 FRM T04.1
STANDARD PARTS
Part Number
X9316Z
X9316W
Maximum Resistance
1Kâ¦
10Kâ¦
Wiper Increments
32.3â¦
323â¦
Notes: (4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
Minimum Resistance
100â¦
100â¦
7000 FRM T05