English
Language : 

X9312 Datasheet, PDF (4/9 Pages) Xicor Inc. – E2POT™ Nonvolatile Digital Potentiometer
X9312
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on CS, INC, U/D and VCC
with Respect to VSS ............................... –1V to +7V
Voltage on VH and VL Referenced to VSS
∆V = |VH–VL|
X9312Z, X9312W, X9312U, and X9312T ....... 15V
Lead Temperature (Soldering 10 seconds) ....... 300°C
Wiper Current ..................................................... ±1mA
ANALOG CHARACTERISTICS
Electrical Characteristics
End-to-End Resistance Tolerance ..................... ±20%
Power Rating at 25°C
X9312Z, .................................................... 225mW
X9312W, X9312U, and X9312T ................. 25mW
Wiper Current ............................................ ±1mA Max.
Typical Wiper Resistance ......................... 40Ω at 1mA
Typical Noise .......................... < –120dB/ Hz Ref: 1V
Resolution
Resistance ............................................................. 1%
Linearity
Absolute Linearity(1) ........................................ ±1.0 Ml(2)
Relative Linearity(3) ..................................... ±0.2 Ml(2)
Test Circuit #1
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those listed in the operational sections of this specifica-
tion is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device
reliability.
Temperature Coefficient
(–40°C to +85°C)
X9312W, X9312U and
X9312T ....................................... +300 ppm/°C Typical
Ratiometric Temperature Coefficient ............ ±20 ppm
Wiper Adjustability
Unlimited Wiper Adjustment (Non-Store operation)
Wiper Position Store Operations ............... 10,000
Data Changes
Physical Characteristics
Marking Includes
Manufacturer’s Trademark
Resistance Value or Code
Date Code
Test Circuit #2
VH
TEST POINT
VW
VL
3865 FHD F04
VH
TEST POINT
VW
FORCE
VL
CURRENT
3865 FHD F05
Notes: (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage
= (Vw(n)(actual) – Vw(n)(expected)) = ±1 Ml Maximum.
(2) 1 Ml = Minimum Increment = RTOT/99.
(3) Relative Linearity is a measure of the error in step size between taps = VW(n+1) – [Vw(n) + Ml] = +0.2 Ml.
4