English
Language : 

X9279 Datasheet, PDF (15/24 Pages) Xicor Inc. – Single Digitally-Controlled (XDCP) Potentiometer
X9279
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1
Parameter
VCC supply current
(active)
ICC2
VCC supply current
(nonvolatile write)
ISB
VCC current (standby)
ILI
Input leakage current
ILO
Output leakage current
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL
Output LOW voltage
VOH
Output HIGH voltage
Min.
Limits
Typ. Max.
3
5
VCC x 0.7
–1
5
10
10
VCC + 1
VCC x 0.3
0.4
Units
mA
mA
µA
µA
µA
V
V
V
Test Conditions
fSCL = 400KHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active, Read
and
fSCL = 400KHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active,
Nonvolatile Write State only)
VCC = +6V; VIN = VSS or VCC;
SDA = VCC; (for 2-Wire, Standby State
only)
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Units
Data changes per bit per register
years
CAPACITANCE
Symbol
CIN/OUT(6)
CIN(6)
Test
Input / Output capacitance (SDA)
Input capacitance (SCL, WP, A2, A1 and A0)
Max.
8
6
Units
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
POWER-UP TIMING
Symbol
tr VCC(6)
tPUR(7)
tPUW(7)
Parameter
VCC Power-up rate
Power-up to initiation of read operation
Power-up to initiation of write operation
Min.
0.2
Max.
50
1
50
Units
V/ms
ms
ms
A.C. TEST CONDITIONS
Input Pulse Levels
Input rise and fall times
Input and output timing level
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Notes: (6) This parameter is not 100% tested
(7) tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be
issued. These parameters are periodically sampled and not 100% tested.
REV 1.1.7 2/6/03
www.xicor.com
Characteristics subject to change without notice. 15 of 24