English
Language : 

X28C256 Datasheet, PDF (13/24 Pages) Xicor Inc. – 5 Volt, Byte Alterable E2PROM
X28C256
WRITE CYCLE LIMITS
Symbol
tWC(7)
tAS
tAH
tCS
tCH
tCW
tOES
tOEH
tWP
tWPH
tWPH2(8)
tDV
tDS
tDH
tDW
tBLC(9)
Parameter
Write Cycle Time
Address Setup Time
Address Hold Time
Write Setup Time
Write Hold Time
CE Pulse Width
OE HIGH Setup Time
OE HIGH Hold Time
WE Pulse Width
WE HIGH Recovery
SDP WE Recovery
Data Valid
Data Setup
Data Hold
Delay to Next Write
Byte Load Cycle
WE Controlled Write Cycle
Min.(9)
0
150
0
0
100
10
10
100
50
1
50
10
10
1
ADDRESS
CE
tAS
tAH
tCS
Typ.(6)
5
tWC
tCH
Max.
10
1
100
Units
ms
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
µs
ns
ns
µs
µs
3855 PGM T11.1
OE
WE
DATA IN
DATA OUT
tOES
tDV
tOEH
tWP
DATA VALID
tDS
tDH
HIGH Z
3855 FHD F06
Notes: (6) Typical values are for TA = 25°C and nominal supply voltage.
(7) tWC is the minimum cycle time to be allowed from the system perspective unless polling techniques are used. It is the maximum
time the device requires to automatically complete the internal write operation.
(8) tWPH is the normal page write operation WE recovery time. tWPH2 is the WE recovery time needed only after the end of issuing
the three-byte SDP command sequence and before writing the first byte of data to the array. Refer to Figure 6 which illustrates
the tWPH2 requirement.
(9) For faster tWC and tBLC, refer to X28HC256 or X28VC256.