X9421 Datasheet, PDF (12/21 Pages) Xicor Inc. – Single Digitally Controlled (XDCP) Potentiometer | |||
|
◁ |
X9421
ABSOLUTE MAXIMUM RATINGS
Temperature under bias . . . . . . . . . . . . â65°C to +135°C
Storage temperature . . . . . . . . . . . . . . â65°C to +150°C
Voltage on SCK any address input
with respect to VSS . . . . . . . . . . . . . . . . . â1V to +7V
âV = | (VH â VL) | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Lead temperature (soldering, 10 seconds) . . . . . . 300°C
IW (10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Any VH/RH, VL/RL, VW/RW . . . . . . . . . . . . VSS to VCC
COMMENT
Stresses above those listed under âAbsolute Maximum
Ratingsâ may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this speciï¬cation) is
not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Min.
0°C
â40°C
Max.
+70°C
+85°C
Device
X9421
X9421-2.7
Supply Voltage (VCC) Limits
5V ±10%
2.7V to 5.5V
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
IW
RW
VTERM
CH/CL/CW
IAL
Parameter
End to End Resistance Tolerance
Power Rating
Wiper Current
Wiper Resistance
Voltage on any VH/RH, VL/RL, VW/RW
Noise
Resolution(4)
Absolute Linearity(1)
Relative Linearity(2)
Temperature Coefficient of RTOTAL
Ratiometric Temperature
Coefficient
Potentiometer Capacitances
Rh, RI, Rw leakage current
Min.
Limits
Typ. Max.
±20
50
±3
150 250
400 1000
VSS
-120
1.6
±300
VCC
±1
±0.2
±20
10/10/25
0.1
10
Units
%
mW
mA
â¦
â¦
V
dBV
%
MI(3)
MI(3)
ppm/°C
ppm/°C
pF
µA
Test Conditions
25°C, each pot
Wiper Current = ± 1mA,
VCC = 5V
Wiper Current = ± 1mA,
VCC = 3V
VSS = 0V
Ref: 1kHz
See Note 5
Vw(n)(actual) â Vw(n)(expected)
Vw(n + 1) â [Vw(n) + MI]
See Note 5
See Note 5
See Circuit #3
Vin = Vss to Vcc. Device is in
stand-by mode.
Notes: (1)
(2)
(3)
(4)
Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when
used as a potentiometer.
Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
MI = RTOT/63 or (VHâVL)/63, single pot
Typical = Individual array resolution.
REV 1.1.6 8/1/02
www.xicor.com
Characteristics subject to change without notice. 12 of 21
|
▷ |