English
Language : 

X76F128 Datasheet, PDF (12/17 Pages) Xicor Inc. – Secure SerialFlash
X76F128
RESET AC SPECIFICATIONS
Power Up Timing
Symbol
Parameter
Min.
Typ(2)
Max.
Units
tPUR(1)
Time from Power Up to Read
1
mS
tPUW(1)
Time from Power Up to Write
5
mS
7052 FM T11
Notes: 1. Delays are measured from the time VCC is stable until the specified operation can be initiated. These parameters are periodically sampled
and not 100% tested.
2. Typical values are for TA = 25˚C and VCC = 5.0V
Nonvolatile Write Cycle Timing
Symbol
Parameter
Min.
Typ.(1)
Max.
Units
tWC(1)
Write Cycle Time
5
10
mS
7052 FM T12
Notes: 1. tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle.
It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
TIMING DIAGRAMS
Bus Timing
tR
tF
tHIGH
tLOW
SCL
tSU:STA
SDA IN
SDA OUT
tHD:STA
tSU:DAT
tHD:DAT
tAA tDH
tSU:STO
tBUF
7052 FM 18
Write Cycle Timing
SCL
SDA
8th bit of last byte
ACK
tWC
Stop
Condition
Start
Condition
7052 FM 19
12