X9409 Datasheet, PDF (11/21 Pages) Xicor Inc. – Quad Digitally Controlled Potentiometers | |||
|
◁ |
X9409 â Preliminary Information
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ....................â65°C to +135°C
Storage temperature .........................â65°C to +150°C
Voltage on SDA, SCL or any address
input with respect to VSS......................... â1V to +7V
â V = |VH â VL |........................................................ 5V
Lead temperature (soldering, 10 seconds).........300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
â40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under âAbsolute Maximum
Ratingsâ may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this speciï¬cation)
is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Device
X9409
X9409-2.7
Supply Voltage (VCC) Limits
5V ±10%
2.7V to 5.5V
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
IW
RW
VTERM
CH/CL/CW
IAL
Parameter
End to end resistance tolerance
Power rating
Wiper current
Wiper resistance
Voltage on any VH/RH or VL/RL pin
Noise
Resolution (4)
Absolute linearity (1)
Relative linearity (2)
Temperature coefficient of RTOTAL
Ratiometric temp. coefficient
Potentiometer capacitances
RH, RL, RW leakage current
Min.
-3
VSS
-1
-0.2
Limits
Typ. Max.
±20
15
+3
50
150
-120
VCC
1.6
+1
+0.2
±300
20
10/10/25
0.1
10
Unit
%
mW
mA
â¦
V
dBV
%
MI(3)
MI(3)
ppm/°C
ppm/°C
pF
µA
Test Conditions
25°C, each pot @5V, 2.5K
IW = ± 3mA, VCC = 3V to 5V
VSS = 0V
Ref: 1kHz
Vw(n)(actual)âVw(n)(expected)
Vw(n + 1)â[Vw(n) + MI]
See Macro Model
VIN = VSS to VCC. Device is
in stand-by mode.
Notes: (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used
as a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potenti-
ometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (VHâVL)/63, single pot
REV 1.6 1/30/03
www.xicor.com
Characteristics subject to change without notice. 11 of 21
|
▷ |