English
Language : 

X9428 Datasheet, PDF (10/20 Pages) Xicor Inc. – Single Digitally Controlled Potentiometer
X9428
XFR Wiper Counter Register (WCR) to Data Register (DR)
S device type
T identifier
device
addresses
S
instruction
opcode
register
addresses
S
S
A
R
T
0
1
0
1
A
3
A
2
0
A
0
A
C
K
1
1
1
0
RR
10
0
0
AT
CO
KP
HIGH-VOLTAGE
WRITE CYCLE
Increment/Decrement Wiper Counter Register (WCR)
S device type device S instruction
S increment/decrement S
T
A
R
T
identifier
0101
addresses
A
3
A
2
0
A
0
A
C
K
opcode
0010
0
0
0
0
A
C
K
(sent by master on SDA)
I/
D
I/
D
.
.
.
.
I/
D
I/
D
T
O
P
SYMBOL TABLE
WAVEFORM INPUTS
OUTPUTS
Must be
steady
May change
from Low to
High
May change
from High to
Low
Don’t Care:
Changes
Allowed
N/A
Will be
steady
Will change
from Low to
High
Will change
from High to
Low
Changing:
State Not
Known
Center Line
is High
Impedance
Guidelines for Calculating Typical Values of Bus
Pull-Up Resistors
120
100
RMIN
=
VCC MAX
IOL MIN
=1.8KΩ
80
RMAX
=
tR
CBUS
60
Max.
Resistance
40
20 Min.
Resistance
0
0 20 40 60
80 100 120
Bus Capacitance (pF)
REV 1.1.5 7/8/03
www.xicor.com
Characteristics subject to change without notice. 10 of 20