X9420 Datasheet, PDF (10/20 Pages) Xicor Inc. – Single Digitally Controlled (XDCP) Potentiometer | |||
|
◁ |
X9420
ABSOLUTE MAXIMUM RATINGS
Temperature under bias.................... â65°C to +135°C
Storage temperature......................... â65°C to +150°C
Voltage on SCK, SCL or any
address input with respect to VSS........... â1V to +7V
Voltage on V+ (referenced to VSS) .........................10V
Voltage on V- (referenced to VSS) ........................ -10V
(V+) â (V-) ..............................................................12V
Any VH/RH, VL/RL, VW/RW ..............................V- to V+
Lead temperature (soldering, 10 seconds) ........ 300°C
IW (10 seconds) ..................................................±6mA
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Min.
0°C
â40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under âAbsolute Maximum
Ratingsâ may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this speciï¬cation) is
not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Device
X9420
X9420-2.7
Supply Voltage (VCC) Limits
5V ±10%
2.7V to 5.5V
ANALOG CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
RTOTAL
IW
RW
Parameter
End to End Resistance
Power Rating
Wiper Current
Wiper Resistance
Vv+
Vv-
VTERM
CH/CL/CW
IAL
Voltage on V+ Pin
X9420
X9420-2.7
Voltage on V- Pin
X9420
X9420-2.7
Voltage on any VH/RH, VL/RL, VW/RW
Noise
Resolution(4)
Absolute Linearity(1)
Relative Linearity(2)
Temperature Coefficient of RTOTAL
Ratiometric Temperature Coefficient
Potentiometer Capacitances
Rh, RI, Rw leakage current
Min.
+4.5
+2.7
-5.5
-5.5
V-
Limits
Typ. Max.
±20
50
±3
150 250
40
100
+5.5
+5.5
-4.5
-2.7
V+
-140
1.6
±1
±0.2
±300
±20
10/10/25
0.1
10
Units
%
mW
mA
â¦
â¦
V
V
V
dBV
%
MI(3)
MI(3)
ppm/°C
ppm/°C
pF
µA
Test Conditions
25°C, each pot
Wiper Current = ± 1mA,
V+/Vâ = ±3V
Wiper Current = ± 1mA,
V+/Vâ = ±5V
Ref: 1kHz
See Note 5
Vw(n)(actual) â Vw(n)(expected)
Vw(n + 1) â [Vw(n) + MI]
See Note 5
See Note 5
See Circuit #3
Vin = V- to V+. Device is in
stand-by mode.
Notes: (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used
as a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (VHâVL)/63, single pot
(4) Typical = Individual array resolution.
REV 1.1.6 7/30/02
www.xicor.com
Characteristics subject to change without notice. 10 of 20
|
▷ |