English
Language : 

890324023011 Datasheet, PDF (6/8 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WCAP-FTX2 Film Capacitors
H Soldering Specifications:
H4: Classification Wave Soldering Profile:
H5: Classification Wave Profile
Profile Feature
Preheat
- Temperature Min (Tsmin)
- Temperature Typical (Tstypical)
- Temperature Max (Tsmax)
- Time (ts) from (Tsmin to Tsmax)
Δ preheat to max Temperature
Peak temperature (Tp)
Time of actual peak temperature (tp)
Ramp-down rate
- Min
- Typical
- Max
Pb-Free Assembly
100°C
120°C
130°C
70 seconds
150°C max.
250°C - 260°C
max. 10 seconds
max. 5 second each wave
~ 2 K/s
~ 3.5 K/s
~ 5 K/s
Time 25°C to 25°C
refer to EN 61760-1:2006
4 minutes
Sn-Pb Assembly
100°C
120°C
130°C
70 seconds
150°C max.
235°C - 260°C
max. 10 seconds
max. 5 second each wave
~ 2 K/s
~ 3.5 K/s
~ 5 K/s
4 minutes
DESCRIPTION
WCAP-FTX2 Film Capacitors
Würth Elektronik eiSos GmbH & Co. KG
1.3
2015-04-16
SSt
PSL
EMC & Inductive Solutions
Max-Eyth-Str. 1
1.2
2014-08-14
SSt
PSL
74638 Waldenburg
Germany
Order.- No.
SIZE
1.1
2014-05-20
SSt
1.0
2014-01-22
SSt
PSL
Tel. +49 (0) 79 42 945 - 0
PSL
www.we-online.com
890324023011
A4
eiSos@we-online.com
REV
DATE
BY
CHECKED
Size: Pitch 10.0 mm - PL 20
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.