English
Language : 

74439344010 Datasheet, PDF (4/7 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-XHMI SMD Power Inductor
P0
D0
P2
D1
A0
P1
End
Feeding direction
T
top cover
tape
K0 T1
T2
Start
Carrier Tape
Cover tape
B
OC
OD
B
B
W3
W**
close to center
W2
No Component
min. 160 mm
Components
Packaging is referred to the international standard IEC 60286 -3:2013
No Component
min. 100 mm
Cover Tape
min. 400 mm
tolerance
size
A0 B0 B1 W T T1 T2 K0 P0 P1 P2 D0
±0,1 ±0,1 typ. ±0,2 ±0,05 typ. ±0,1 ±0,1 ±0,1 ±0,1 ±0,1 +0,1/ -0,0
6030 7.6 7.5 8.65 16 0.4 0.15 3.8 3.6 4 12 2 1.5
6060 7.6 7.5 9.35 16 0.4 0.15 6.5 6.4 4 12 2 1.5
8080 9 8.85 13 24 0.6 0.1 8 7.9 4 16 2 1.5
1090 12.4 11.3 14.8 24 0.5 0.2 10.3 9.80 4 20 2 1.5
D0 / 2
+0,05/ -0,0
0.75
0.75
0.75
0.75
D1 d E1 E2 F Tape Type 2a
±0,1 +0,05 ±0,1 ±0,1 ±0,1
1.5 0.2 0.75 12.5 7.5 Polystyrene
1.5 0.2 0.75 12.5 7.5 Polystyrene
1.5 0.2 1.75 22.25 11.5 Polystyrene
1.5 0.2 1.75 22.25 11.5 Polystyrene
VPE / packaging unit
pcs.
1000
700
500
300
tolerance
Tape width
16 mm
24 mm
A
B
±2,0 min.
330 1.5
330 1.5
C
D
N
W1
±0,8 min. ±2,0 +2
13
20.2 60
16.40
13
20.2 60
24.4
W2 W3 W3
max. min. max.
22.4 15.9 19.40
30.4 23.9 27.4
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
KaS
CHECKED
DDe
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WE-XHMI SMD Power Inductor
ORDER CODE
74439344010
SIZE
6030
REVISION
001.000
STATUS
Valid
DATE
BUSINESS UNIT
PAGE
2016-04-01
eiSos
4/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.