English
Language : 

744230181 Datasheet, PDF (4/6 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-CNSW SMD Common Mode Line Filter
H Soldering Specifications:
H1: Classification Reflow Profile for SMT components:
H2: Classification Reflow Profiles
Profile Feature
Preheat
- Temperature Min (Tsmin)
- Temperature Max (Tsmax)
- Time (ts) from (Tsmin to Tsmax)
Ramp-up rate (TL to TP)
Liquidous temperature (TL)
Time (tL) maintained above TL
Peak package body temperature (Tp)
Time within 5°C of actual peak temperature (tp)
Ramp-down rate (TP to TL)
Time 25°C to peak temperature
refer to IPC/JEDEC J-STD-020D
Pb-Free Assembly
150°C
200°C
60-180 seconds
3°C/ second max.
217°C
60-150 seconds
See Table H3
20-30 seconds
6°C/ second max.
8 minutes max.
H3: Package Classification Reflow Temperature
Package Thickness
PB-Free Assembly
< 1.6 mm
PB-Free Assembly
1.6 - 2.5 mm
PB-Free Assembly
≥ 2.5 mm
refer to IPC/JEDEC J-STD-020D
Volume mm³
<350
260°C
260°C
250°C
Volume mm³
350 - 2000
260°C
250°C
245°C
Volume mm³
>2000
260°C
245°C
245°C
DESCRIPTION
WE-CNSW SMD Common Mode Line Filter
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
2.1
2012-07-17
SSt
SSt
74638 Waldenburg
Germany
Order.- No.
SIZE
2.0
2012-07-17
SSt
1.0
2010-09-30
SBa
SBa
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
744230181
A4
eiSos@we-online.com
REV
DATE
BY
CHECKED
Size: 0603
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.