English
Language : 

744839003460 Datasheet, PDF (3/5 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – DC Resistance
Classification Wave Soldering Profile:
tp
Tp
First Wave
Second Wave
Ts max
Ts typical
Ts min
Preheat area
Cool down area
Time
typical temperature procedure
min temperature procedure
max temperature procedure
Classification Wave Soldering Profile:
Profile Feature
Pb-Free Assembly
Preheat Temperature Min
Preheat Temperature Typical
Preheat Temperature Max
Preheat Time ts from Ts min to Ts max
Peak temperature
Ts min
Ts typical
Ts max
ts
Tp
100 °C
120 °C
130 °C
70 seconds
250 °C - 260 °C
Time of actual peak temperature
tp
max. 10 seconds
max. 5 seconds each wave
Ramp-down Rate, Min
Ramp-down Rate, Typical
Ramp-down Rate, Max
Time 25°C to 25°C
~ 2 K/ second
~ 3.5 K/ second
~ 5 K/ second
4 minutes
refer to EN61760-1:2006
Sn-Pb Assembly
100 °C
120 °C
130 °C
70 seconds
235 °C - 260 °C
max. 10 seconds
max. 5 seconds each wave
~ 2 K/ second
~ 3.5 K/ second
~ 5 K/ second
4 minutes
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
KaS
CHECKED
HasA
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WE-TPBHV Three-Phase Common
Mode Power Line Choke
ORDER CODE
744839003460
SIZE
4XL
REVISION
001.000
STATUS
Valid
DATE
BUSINESS UNIT
PAGE
2016-09-16
eiSos
3/5
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.