Electrical & Optical Properties:
Properties
Peak Wavelength
Centroid Wavelength
Radiant Flux
Radiant Intensity
Forward Voltage
Spectral Bandwidth
Reverse Current
Viewing Angle
Test conditions
min.
1000 mA
1000 mA
1000 mA
1000 mA
1000 mA
1000 mA
λPeak
λCentroid
Φe
440
Ie
VF
1.5
Δλ
5V
1000 mA
IREV
2θ50%
Value
typ.
945
940
300
1.9
45
10
90
Viewing Angle:
Unit
max.
nm
nm
680
mW
mW/sr
2.5
V
nm
μA
-45°
100
°
90
Properties
Test Conditions Bin
Value
Unit
80
min.
typ.
max.
70
Forward Voltage VF
1000 mA
1
1.5
2
1.7
3
1.9
4
2.1
1.7
V
60
1.9
V
50
2.1
V
2.3
V
40
5
2.3
2.5
V
30
Radiant Flux Φe
1000 mA
A
440
B
500
C
560
500
mW
20
560
mW
10
600
mW
D
600
680
mW
-90
0°
10°
20°
30°
40°
45°
50°
60°
70°
80°
90°
0 10 20 30 40 50 60 70 80 90 100
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
KaS
CHECKED
ZAn
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WL-SIMW SMD Infrared Ceramic
Waterclear
ORDER CODE
15435394A9050
SIZE
3535
REVISION
001.000
STATUS
Valid
DATE
BUSINESS UNIT
PAGE
2015-11-10
eiPal
2/9
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.