A Dimensions: [mm]
B Recommended hole pattern: [mm]
C Schematic:
D1 Electrical Properties:
Properties
Test conditions
Value Unit
Capacitance
1 V/ 1 kHz ± 0.2 kHz C 0.0100 µF
Rated voltage
Isolation Resistance
Dissipation factor
1 min @ 100V (DC)
@ 1 kHz
UR
275 V (AC)
RIso > 30000 MΩ
DF < 0.10 %
Dissipation factor
@ 10 kHz
DF < 0.10 %
Dissipation factor
@ 100 kHz
DF < 0.50 %
Rate of Voltage Rise
dV/ dt 500 V/ µs
Dielectric strength Pin to Pin
1 minute
1333 V (DC)
Dielectric strength Pin to Case
1 minute
2000 V (AC)
Tol.
± 10%
min.
max.
max.
max.
max.
E General information:
X2-Safety Class Capacitor; MKP - Metallized Polypropylene
Storage Conditions: 35°C, <45% RH
Operating Temperature: -40°C to +105°C
Climate category: 40/ 105/ 56/ B
Maximum Selfheating (rated): 7°C
Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
FIT according to separate documentation
DESCRIPTION
P ±0.5
L ±0.5
H ±0.5
W ±0.5
PL ±0.05
Pin Ø ±0.05
d1
10.0
13.0
WCAP-FTX2 Film Capacitors
11.0
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
5.0
Max-Eyth-Str. 1
4.0
1.2
2015-04-16
SSt
PSL
74638 Waldenburg
Germany
Order.- No.
SIZE
0.6
0.9
1.1
2014-08-14
SSt
1.0
2014-05-14
SSt
PSL
Tel. +49 (0) 79 42 945 - 0
PSL
www.we-online.com
eiSos@we-online.com
890324023006CS
A4
REV
DATE
BY
CHECKED
Size: Pitch 10.0 mm - PL 4
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.