English
Language : 

885362211011 Datasheet, PDF (1/6 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WCAP-CSSA Ceramic Capacitors
A Dimensions: [mm]
B Recommended land pattern: [mm]
C Schematic:
D1 Electrical Properties:
Properties
Test conditions
Capacitance 1±0.2 Vrms, 1 kHz ±10% C
Rated voltage
UR
Impulse Voltage
UImp
Dissipation factor 1±0.2 Vrms, 1 kHz ±10% DF
Isolation Resistance Apply UR for 60 s max. RIso
Dielectric Strength 1)
Iload
1) Dielectric Strength
X-Cap: 1075 V (DC) 60s @ dV ≤ 150 V (r.m.s)/ sec.
Y-Cap: 1500 V (AC) 60s @ dV ≤ 150 V (r.m.s)/ sec.
Value
1000
250
2500
≤ 2.5
≥ 10
≤ 0.05
Unit
pF
V (AC)
V (DC)
GΩ
A
Tol.
± 10%
max.
max.
typ.
E General information:
Safety Certified MLCC
Ceramic Type:
X7R Class X2 / Y3
Temperature Coeffecient: ± 15% max.
Storage Conditions:
35°C, <45% RH
Operating Temperature:
-55 °C up to +125 °C
Dielectric Strength:
General Test conditions:
5 sec. @250% UR; Charge & Discharge Current < 50mA
25°C, 30-70% RH; if not specified differently
FIT according to
separate documentation
DESCRIPTION
L ± 0.5
W ± 0.4
H ± 0.2
E
l
p
w
4.5
3.2
WCAP-CSSA Ceramic Capacitors
1.6
Würth Elektronik eiSos GmbH & Co. KG
0.26
EMC & Inductive Solutions
Max-Eyth-Str. 1
5.30
74638 Waldenburg
Germany
Order.- No.
SIZE
3.50
3.80
1.0
2014-11-21
SSt
Tel. +49 (0) 79 42 945 - 0
PSL
www.we-online.com
eiSos@we-online.com
885362211011
A4
REV
DATE
BY
CHECKED
Size: 1812
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before