A Dimensions: [mm]
B Recommended land pattern: [mm]
C Schematic:
D1 Electrical Properties:
Properties
Test conditions
Capacitance 1±0.2 Vrms, 1 kHz ±10% C
Rated voltage
UR
Dissipation factor 1±0.2 Vrms, 1 kHz ±10% DF
Isolation Resistance Apply UR for 120 s max. RIso
Value
10000
50
≤ 2.5%
≥ 10
Unit
pF
V (DC)
GΩ
Tol.
± 10%
max.
typ.
E General information:
General Purpose MLCC
Ceramic Type:
Temperature Coeffecient:
Storage Conditions:
Operating Temperature:
Dielectric Strength:
General Test conditions:
FIT according to
X7R Class II
± 15% max.
35°C, <45% RH
-55 °C up to +125 °C
5 sec. @250% UR; Charge & Discharge Current < 50mA
25°C, 30-70% RH; if not specified differently
separate documentation
DESCRIPTION
Component Marking:
L ± 0.1
1.6
WCAP-CSGP Ceramic Capacitors
W ± 0.1
0.8
Würth Elektronik eiSos GmbH & Co. KG
H +0.15/-0.10
0.8
EMC & Inductive Solutions
Max-Eyth-Str. 1
E ± 0.15
0.4
74638 Waldenburg
Germany
Order.- No.
SIZE
l - Reflow
p - Reflow
2.30
l - Wave
2.40
0.70
p - Wave
1.00
1.0
2014-11-06
SSt
Tel. +49 (0) 79 42 945 - 0
PSL
www.we-online.com
eiSos@we-online.com
885012206089
A4
w - Reflow
0.80
w - Wave
0.80
REV
DATE
BY
CHECKED
Size: 0603
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.