English
Language : 

875105344006 Datasheet, PDF (1/8 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WCAP-PSLP Aluminum Polymer Capacitors
A Dimensions: [mm]
B Recommended hole pattern: [mm]
C Schematic:
D1 Electrical Properties:
Properties
Capacitance
Rated voltage
Leakage current
Dissipation factor
ESR
Ripple current
Test conditions
0.25V; 120Hz
after 2 min.
120 Hz
100 kHz
100kHz @105°C
C
UR
ILeak
DF
RESR
Iripple
Value
47
16
400
8
30
2200
Unit
µF
V (DC)
μA
%
mΩ
mA
Tol.
± 20%
max.
max.
typ.
max.
max.
E General information:
Aluminium Polymer Capacitors
Storage Conditions:
Operating Temperature:
Load Life:
Test conditions of Electrical Proper-
ties:
FIT according to
35°C, <45% RH
-55 °C up to +105 °C
2000 h @ +105°C / 16 V (DC)
20°C, 33% RH; if not specified differently
separate documentation
DESCRIPTION
L max.
D ±0.5
A ±0.2
B ±0.2
C max.
W ±0.1
E ±0.05
P ±0.2
5.8
6.3
6.6
6.6
0.15
0.65
a
0.35
b
2.1
c
WCAP-PSLP Aluminum Polymer Capacitors
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Order.- No.
SIZE
2.1
Tel. +49 (0) 79 42 945 - 0
3.5
1.0
2014-11-11
SSt
PSL
www.we-online.com
eiSos@we-online.com
875105344006
A4
1.6
REV
DATE
BY
CHECKED
Size: 6.3 x 5.8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.