English
Language : 

8231614 Datasheet, PDF (1/3 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – ESD Suppressor WE-VE femtoF
Customer :
Ordercode:
Description :
Specification for release
8231614
ESD Suppressor WE-VE femtoF
A Dimensions:
Size 0603
A
1.6 ± 0.2
mm
B
0.8 ± 0.2
mm
C
0.9 max
mm
D
0.3 ± 0.2
mm
B Electrical properties:
Properties
Test Conditions
DC operating voltage
capacitance
1 MHz
capacitance
1 MHz
leakage current
12 VDC
trigger voltage
TLP measurement
clamping voltage
8kV Contact, 30ns
ESD withstand
8kV Contact
VDC
Ctyp
Cmax
IL max
vTr
vCl
Value
14
0.05
0.15
0.05
275
45
2000
@@FRM 1 @@
C Soldering spec.:
Unit
Tol.
V
max
2.2 - 2.6
a [mm]
pF
typ
0.7
b [mm]
pF
max
0.7
c [mm]
µA
max
V
typ
V
typ
min
D Test equipment:
Keithley 2410 for leakage Current
Agilent 4396B Analyzer for Capacitance
F Material & approvals:
Base material:
Ceramic
General Release:
E Test conditions:
Humidity:
Temperature:
G General specifications:
Storage temperature:
Max. operating temperature:
Customer
33%
+20°C
-20°C … +60°C
-40°C … +85°C
.......................................................................
Date
........................................................................
Signature
Würth Elektronik
SSt
Version 2
2010-06-25
.......................................................................
Checked
........................................................................ JB
Approved
Name
Version 1
Modification
2008-09-02
Date
This electronic component has been designed and developed for usage in general electronic equipment. Before incorporating this component into any equipment where higher safety and
reliability is especially required or if there is the possibility of direct damage or injury to human body, for example in the range of aerospace, aviation, nuclear control, submarine,
transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc, Würth Elektronik eiSos GmbH must be
informed before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that
require high safety and reliability functions or performance.
Würth Elektronik eiSos GmbH & Co. KG
D-74638 Waldenburg · Max-Eyth-Strasse 1 · Germany · Phone (+49) (0) 7942 - 945 - 0 · Fax (+49) (0) 7942 - 945 - 400
http://www.we-online.com
PAGE 1 OF 3