English
Language : 

782422331 Datasheet, PDF (1/7 Pages) Wurth Elektronik GmbH & Co. KG, Germany. – WE-CBA SMD EMI Suppression Ferrite Bead
A Dimensions: [mm]
B Recommended land pattern: [mm]
C Schematic:
D Properties:
Properties
Test conditions
Value
Unit
Impedance
100 MHz
Z
330
Ω
Maximum Impedance
300 MHz
Z
640
Ω
Rated Current
DC Resistance
ΔT = 20K
IR
300
mA
@ 20°C
RDC
0.50
Ω
Type
Wide Band
Tol.
±25%
typ.
max.
max.
E General information:
Do not use this part beyond the Rated Current, as this will create
excessive heat and can harm the component
•Ambient temperature: -55°C to +85°C/ +105°C (refering to IR)
•Operating temperature: -55°C to +125°C
•Storage temperature (on tape & reel): -20°C to +40°C; 75% RH max.
•Test conditions of Electrical Properties: 20°C, 33% RH
if not specified differently
•AEC-Q 200 qualified
DESCRIPTION
1.8
2014-03-11
SSt
BMoe
1.7
2013-12-19
SSt
SSt
1.6
2013-12-04
SSt
BMoe
Würth Elektronik eiSos GmbH & Co. KG
1.5
2013-04-10
SSt
SSt
EMC & Inductive Solutions
Max-Eyth-Str. 1
1.4
2013-03-06
SSt
SSt
74638 Waldenburg
1.3
2013-02-14
SSt
Germany
SSt
Tel. +49 (0) 79 42 945 - 0
1.2
2012-12-10
SSt
SSt
www.we-online.com
eiSos@we-online.com
REV
DATE
BY
CHECKED
WE-CBA SMD EMI Suppression Ferrite
Bead
Order.- No.
SIZE
782422331
A4
Size: 0402
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use.
Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before
the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.