Electrical Properties:
Properties
Inductance
Turns Ratio
Saturation Current
DC Resistance 1
DC Resistance 2
DC Resistance 3
DC Resistance 4
Leakage Inductance
Insulation Test Voltage
Test conditions
Value
Unit Tol.
100 kHz/ 100 mV L
1500
µH ±10%
n 160 : 10 : 7 : 16
±3%
|ΔL/L| < 20 %
ISAT
RDC
RDC
RDC
RDC
100 kHz/ 100 mV LS
W1,4 => W2,3 UT
0.8
6500
86
24
370
60
4000
A typ.
mΩ max.
mΩ max.
mΩ max.
mΩ max.
µH max.
V (AC)
0,7 ± 0,05
Schematic:
9
1
7
12
Scale - 1,5:1
4
11
Scale - 1,5:1
1
2
2
3,4
3
5,6
General Information:
It is recommended that the temperature of the component does not exceed +125°C under worst
case conditions
Storage Temperature (in original
packaging)
-20 °C up to +60 °C
Operating Temperature
-40 °C up to +125 °C
Test conditions of Electrical Properties: +20°C, 33% RH if not specified differently
Designed to comply with the following requirements as defined by IEC61558-2-16; Reinforced
insulation for a working voltage of 375 VRMS
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
SSt
CHECKED
SSt
GENERAL TOLERANCE
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WE-UOST Universal Offline
Standard Transformers
SIZE
REVISION
STATUS
EE16/8/5 001.004
Draft
ORDER CODE
760875532
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
2015-11-10
eiSos
1/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.